TYCON TP-SCPOE-12XX Series Solar & PoE Battery Charger USER’S MANUAL TYCON POWER SYSTEMS
User’s Manual TP-SCPOE-12XX Series Features: Battery Polarity Reverse Protection Battery Over Charge Protection Battery Over Discharge Protection Solar Panel Polarity Reverse Protection Solar Panel Over Charge Protection Output Short Circuit Protection Output Over Voltage Protection POE Output Short Circuit Protection POE Output Support 802.3af Function (TP-SCPOE-1248D) Two Input method: (1)Solar Panel (2)PoE Power source (Always Solar First.
User’s Manual TP-SCPOE-12XX Series Panel Description: Item Name Descriptions 1 POE : PoE power input indicator: the LED lights when the PoE input jack (the lower jack) has 18V~57V input. 2 SOL : Solar power input indicator: the LED lights when SOL terminal is connecting to a solar panel and the solar panel input voltage is over 12V.
User’s Manual TP-SCPOE-12XX Series Operation Guide NOTICE: 1. Connect the battery to the BAT terminal. Make sure the polarities are correctly connected. Sequentially connect the solar panel to SOL terminal and connect POE source to PoE input (lower) jack. (If solar panel or PoE source is installed before the battery, and if the polarities of the battery be reversed, then the fuse will be burnt.) 2. Make sure the battery is properly connected to the unit.
User’s Manual TP-SCPOE-12XX Series Electrical specifications 1.0 INPUT 1.1 Input Source types: A. Solar Panel B. POE 1.2 Input Voltage: A. Solar Panel: 18V~36Vmax B. POE: 18V~57V 2.0 OUTPUT Model TP-SCPOE-1212 TP-SCPOE-1218 TP-SCPOE-1224 TP-SCPOE-1248 TP-SCPOE-1248D Output 1* (at rear terminal) 12V/1.5A (as Bat. Volt.)* 12V/1.5A (as Bat. Volt.)* 12V/1.5A (as Bat. Volt.)* 12V/1.5A (as Bat. Volt.)* 12V/1.5A (as Bat. Volt.)* Output 2 (at upper RJ45) 12V/1.0A (as Bat. Volt.)* 18V/1.
User’s Manual TP-SCPOE-12XX Series 5.3 Battery Over Charge Protection: Fuse control, over 10A, the fuse will be burnt. 5.4 Solar Panel Polarity Reverse Protection: When solar panel polarities be reversed, the charger stop output, it won’t damage the charger or end device 5.5 Solar Panel Over Charge Protection: When charge current over 10A, the fuse will be burnt. 5.