Specification

RA Flashing
Issue Date: 2-13-13
Page 3 of 6
Storage Procedures
Store in accordance with local regulations. Store in original container protected from direct sunlight in a
dry cool and well ventilated area a
way from incompatible materials and food and drink. Keep container
tightly closed and sealed until ready to use. Do not store in unlabeled containers.
Section 8 - Exposure Controls/Personal Protection
Component Exposure Limits
Component
CAS
Exposure Limits
Petroleum
Bitumen
8052-42-4
ACGIH TLV ( United States, 1/2008)
TWA: 0.5 mg/m3 8 hour(s) Form: Fume
NIOSH REL ( United States, 12/2001)
CEIL: 5 mg/m3 15 minute(s). Form: Fume
Engineering Controls
Use only with adequate ventilation. If user operations generate dust, fumes, gas, vapor or mist, use
process enclosures, local exhaust ventilation or other engineering controls to keep worker exposure to
airborne contaminates below any recommended or statutory limits.
Hygiene Measures
Wash hands, forearms and face thoroughly after handling chemical products, before eating, smoking,
and using the lavatory and at the end of the working period. Appropriate techniques should be used to
remove potentially contaminated clothing. Wash contaminated clothing before reusing. Ensure that
eyewash stations and safety showers are close to the work station location.
Personal Protective Equipment
Personal Protective Equipment-Eyes/Face
Safety Glasses
Personal Protective Equipment-Skin
Overall buttoned at the neck and wrist and chemical resistant gloves.
Personal Protective Equipment-Respiratory
None usually required
Personal Protective Equipment-General
Follow individual plant safety rules.
Section 9 - Physical & Chemical Properties
Appearance:
Bitumen Adhesive on Polymer
Film with Liner
Odor:
Asphaltic
Physical State:
Solid
pH:
Not Applicable
Vapor Pressure:
NIL
Evaporation Rate:
Not Applicable
Boiling Point:
Not Applicable
Melting Point:
Not Applicable
Solubility (H
2
O):
Negligible
Specific Gravity:
Not Applicable
Vapor Density:
Not Applicable
Percent Volatiles:
NIL
Packing Density:
Not Applicable
.