SDS

Safety Data Sheet
According to HCS-2012 APPENDIX D TO ยง1910.1200
Version: 1.0/EN
Revision date: 15-Nov-2017
Product name: Rechargeable Lithium -ion Polymer Battery
Printing date: 15-Nov-2017
-- Page 4 / 11 --
perforation of stomach or esophagus should be investigated. Do not give chemical antidotes.
Asphyxia from glottal edema may occur. Marked decrease in blood pressure may occur with moist
rales, frothy sputum, and high pulse pressure.
5. Fire-fighting measures
(a) Extinguishing media
Suitable extinguishing media:
Use foam, dry powder or dry sand, CO
2
as appropriate.
Unsuitable extinguishing media:
No information available.
(b) Special hazards arising from the chemical
Under fire conditions, batteries may burst and release hazardous decomposition products when exposed to a fire
situation. This could result in the release of flammable or corrosive materials. Hazardous combustion products: CO,
CO
2
, Metal oxides, Irritating fumes
(c) Special protective equipment and precautions for fire-fighters
6. Accidental release measures
(a) Personal precautions, protective equipment and emergency procedures
Personal Precautions
In case of rupture. Attention! Corrosive material. Avoid contact with skin,
eyes or clothing. Ensure adequate ventilation. Use personal protective
equipment as required. Evacuate personnel to safe areas. Keep people away
from and upwind of spill/leak.
Other Information
Refer to protective measures listed in Sections 7 and 8.
(b) Environmental Precautions
Environmental Precautions
Refer to protective measures listed in Sections 7 and 8. Prevent further leakage
or spillage if safe to do so. Should not be released into the environment. Do not
allow to enter into soil/subsoil. Prevent product from entering drains.
(c) Methods and materials for containment and cleaning up
Methods for Containment
Prevent further leakage or spillage if safe to do so.
Methods for cleaning up
Pick up and transfer to properly labeled containers.
7. Handling and storage
(a) Precautions for safe handling
Handling
In case of rupture. Handle in accordance with good industrial hygiene and
safety practice. Avoid contact with skin, eyes or clothing. Use personal
protection equipment.