User's Manual Part 2

11.2: GAP Commands Chapter 11: AT Commands Reference
26
store_in_startup_database enumerator 0: The setting will only be valid for the
current power cycle.
1: The Serial Port Adapter will remember
the setting between power cycles. The
settings database in the Serial Port
Adapter will be updated.
Responses Description
<CR><LF>OK<CR><LF> Successful response.
<CR><LF>ERROR<CR><LF> Error response.
Model Constraint
cB-OEMSPA311
cB-OEMSPA331
cB-OEMSPA312
cB-OEMSPA332
Limited discoverability mode not supported.
Read_Connectability_Mode (AT*AGCM?)
AT Command Description
AT*AGCM?<CR> This command reads the current GAP connectability
mode.
Responses Description
<CR><LF>*AGCM:<connectability_mode><CR><LF>OK<CR><LF> Successful response.
<CR><LF>ERROR<CR><LF> Error response.
Result Pa-
rameters
Type Value
connectablilty_mode enumerator 1: GAP non-connectable mode
2: GAP connectable mode (default value)
Write_Connectability_Mode (AT*AGCM=)
AT Command Description
AT*AGCM=<connectability_mode>,
<store_in_startup_database><CR>
Writes the GAP connectability mode.
Command Pa-
rameters
Type Value
connectablilty_mode enumerator 1: GAP non-connectable mode
2: GAP connectable mode (default value)