User's Manual Part 2

11.4: Data Mode Commands Chapter 11: AT Commands Reference
47
<connect_scheme>, <up-
date_remote_peer_on_incoming>, <de-
vice_name>,
<store_in_startup_database><CR>
dress, connect scheme and device name of the
currently selected default remote peer.
Command Pa-
rameters
Type Value
peer_id integer The peer ID can be between 0 and the
value written by the Write_No_Of_Peers
command –1 or read by the
Read_No_Of_Peers command –1.
bd_addr Bd_Addr Bluetooth device address of the default
remote peer.
connect_scheme integer See Read_Default_Remote_Peer.
update_remote_peer_on_incoming enumerator See Read_Default_Remote_Peer.
device_name string See Read_Default_Remote_Peer.
store_in_startup_database enumerator 0: The setting will only be valid for the
current power cycle.
1: The Serial Port Adapter will remember
the setting between power cycles. The
settings database in the Serial Port
Adapter will be updated.
Responses Description
<CR><LF>OK<CR><LF> Successful response.
<CR><LF>ERROR<CR><LF> Error response.
Model Constraint
cB-OEMSPA311
cB-OEMSPA331
cB-OEMSPA312
cB-OEMSPA332
The parameter <device_name> is only used when bit 3 in the
connect scheme is set. Max length is 32 characters.
cB-OEMSPA13
cB-OEMSPA33
Connect to name functionality is not supported. This means that
bit 3 in the connect scheme parameter is ignored.
Read_Inactivity_Tick (AT*ADIT?)
AT Command Description
AT*ADIT?<CR> This command reads the current inactivity tick setting. If there is
no data activity between two consecutive ticks the Serial Port
Adapter will automatically disconnect the current data mode
connection(s).
Responses Description
<CR><LF>*ADIT:<inactivity_tick><CR><LF>OK<CR><LF> Successful response
<CR><LF>ERROR<CR><LF> Error message.
Response
Parameters
Type Value