User's Manual Part 2

11.6: Miscellaneous Commands Chapter 11: AT Commands Reference
58
AT*AMMP=<max_output_power>,
<store_in_startup_database><CR>
Set the maximum output power to be used by
the Serial Port Adapter when communicating.
Note that not all Serial Port Adapter models
support output power control.
Command Pa-
rameters
Type Value
max_output_power integer See Read_Max_Output_Power.
store_in_startup_database enumerator 0: The setting will only be valid for the current
power cycle.
1: The Serial Port Adapter will remember the
setting between power cycles. The settings
database in the Serial Port Adapter will be
updated.
Responses Description
<CR><LF>OK<CR><LF> Successful response
<CR><LF>ERROR<CR><LF> Error message.
Model Constraint
cB-OEMSPA311
cB-OEMSPA331
cB-OEMSPA312
cB-OEMSPA332
Not supported.
Read_Esc_Sequence_Timing (AT*AMET?)
AT Command Description
AT*AMET?<CR> For an escape sequence to be valid, a period of no
data activity is required before and after the escape
sequence. This command reads the minimum time of
no data activity required before and after the escape
sequence.
Responses Description
<CR><LF>*AMET:<min_before_time>, <min_after_time>
<CR><LF>OK<CR><LF>
Successful response
<CR><LF>ERROR<CR><LF> Error message.
Response Parame-
ters
Type Value
min_before_time integer 50-5000 ms.
The default value is 1000.
min_after_time integer 50-5000 ms.
The default value is 1000.