User's Manual Part 2

11.6: Miscellaneous Commands Chapter 11: AT Commands Reference
62
Responses Description
<CR><LF>OK<CR><LF> Successful response
<CR><LF>ERROR<CR><LF> Error message.
Model Constraint
cB-OEMSPA311
cB-OEMSPA331
cB-OEMSPA312
cB-OEMSPA332
Only available in production.
Read_Watchdog_Settings (AT*AMWS?)
AT Command Description
AT*AMWS?<CR> Read current watchdog settings.
Watchdog settings are only active in data mode and
not AT or ECI mode.
Responses Description
<CR><LF>*AMWS: <bt_write_timeout>,
<bt_inactivity_timeout>, <bt_connect_timeout>,
<bt_disconnect_reset>, <reset><CR><LF>OK<CR><LF>
Successful response
<CR><LF>ERROR<CR><LF> Error message.
Response Parame-
ters
Type Value
bt_write_timeout integer Time in seconds before SPA discon-
nects if out of credits.
0: Disabled (default value)
> 0: Timeout in seconds
bt_inactivity_timeout integer Time in seconds before SPA discon-
nects if no activity.
0: Disabled (default value)
> 0: Timeout in seconds
bt_connect_timeout integer Max connection time in seconds before
a connection is terminated.
0: Disabled (default value)
> 0: Timeout in seconds
bt_disconnect_reset integer 0: Disabled (default value)
1: An SPA enabled, as a server will
reset on a terminated connection.
reset integer Will always read a value of 0.
If written, 1 means reset of module.
Other parameters are then ignored.
Model Constraint
cB-OEMSPA311
cB-OEMSPA331
cB-OEMSPA312
cB-OEMSPA332
Not supported