User's Manual Part 2

11.6: Miscellaneous Commands Chapter 11: AT Commands Reference
65
Responses Description
<CR><LF>OK<CR><LF> Successful response
<CR><LF>ERROR<CR><LF> Error message.
Model Constraint
cB-OEMSPA13
cB-OEMSPA33
Not supported.
Read_Link_Policy (AT*AMLP?)
AT Command Description
AT*AMLP?<CR> Read current Link Policy.
Responses Description
<CR><LF>*AMLP: <link_policy>, <parame-
ter><CR><LF>OK<CR><LF>
Successful response
<CR><LF>ERROR<CR><LF> Error message.
Response Parame-
ters
Type Value
link_policy integer See Write_Link_Policy command.
parameter integer See Write_Link_Policy command.
Model Constraint
cB-OEMSPA13
cB-OEMSPA33
Not supported.
Write_Link_Policy (AT*AMLP=)
AT Command Description
AT*AMLP=<link_policy>, <parameter>,
<store_in_startup_database><CR>
Write link policy.
The link policy can be chosen to optimize the
link for a specific application. The link policy can
be chosen to reduce power consumption, get
faster response times or to optimize the SPA as
either sender or receiver.
Note!
Using other link policies than the default
may lead to interoperability problems. Verify
that the chosen link policy works with other
devices your application is intended to inter-
operate with. If not, use the default link pol-
icy.
Link policy 3 or 4 gives the shortest response
times.
Link policy 8 combined with stop mode (AMPM:
3) gives the lowest power consumption.