User's Manual

-
- Page of 14 21
Guidance on how the End product that utilise this module is marked in accordance with the
R&TTE directive is found in the following links:
http://ec.europa.eu/enterprise/sectors/rtte/documents/index_en.htm#h2-5
http://ec.europa.eu/enterprise/sectors/rtte/documents/guidance/index_en.htm
A direct link to the quick guide to the marking requirements can be found here:
http://ec.europa.eu/enterprise/sectors/rtte/files/guidance/guidance_en.pdf
The ODIN-W161 uses harmonised frequency bands thus it is comprised by subclass H01 of class 2
equipment, for which notification in accordance with article 6(4) of the R&TTE directive is not
necessary.
A definition of subclasses of Class 2 equipment can be found in the following link:
http://ec.europa.eu/enterprise/sectors/rtte/files/rtte-subclass2_en.pdf
The table below shows the restrictions when operating the module in WLAN mode within the
European countries
band Channel number Channel frequency Indoor Use allowed Outdoor Use allowed Radio Equipment Class
ISM 1 - 11 2412 - 2462 MHz Yes Yes 1
U-NII 1 36 - 48 5180 - 5240 MHz Yes No 2
U-NII 2 52 - 64 5260 - 5320 MHz Yes No 2
U-NII 2e 100 - 140 5500 - 5700 MHz Yes Yes 1
U-NII 3 149 - 165 5745 - 5825 MHz No No -
5.1.2 Declaration of Conformity
We, u-blox Malmö AB, of
Östra Varvsgatan 4, 5tr
SE-211 75 Malmö, Sweden
declare under our sole responsibility that our product:
ODIN-W161
to which this declaration relates, conforms to the following product specifications:
R&TTE Directive 1999/5/EC
Effective use of frequency spectrum:
EN 300 328 V1.8.1 (2012-06)
EN 301 893 V1.7.1 (2012-06)