User's Manual

TOBY-R2 series - System Integration Manual
UBX-16010572 - R04 System description
Page 32 of 147
Figure 16 describes the TOBY-R2 series modules switch-off sequence started by means of the PWR_ON input
pin, allowing storage of current parameter settings in the module’s non-volatile memory and a proper network
detach, with the following phases:
A low pulse with appropriate time duration (see TOBY-R2 series Data Sheet [1]) is applied at the PWR_ON
input pin, which is normally set high by an internal pull-up: the module starts the switch-off routine when
the PWR_ON signal is released from the low logical level.
At the end of the switch-off routine, all the digital pins are tri-stated and all the internal voltage regulators
are turned off, including the generic digital interfaces supply (V_INT), except the RTC supply (V_BCKP).
Then, the module remains in power-off mode as long as a switch-on event does not occur (e.g. applying a
proper low level to the PWR_ON input, or applying a proper low level to the RESET_N input), and enters
not-powered mode if the supply is removed from the VCC pins.
VCC
V_BCKP
PWR_ON
RESET_N
V_INT
Internal Reset
System State
BB Pads State
OFF
Tristate / Floating
ON
Operational -> Tristate
Operational
0 s
~2.5 s
~5 s
The module starts
the switch-off routine
VCC
can be removed
Figure 16: TOBY-R2 series switch-off sequence by means of PWR_ON pin
The Internal Reset signal is not available on a module pin, but the application can monitor the V_INT pin
to sense the end of the switch-off sequence.
The duration of each phase in the TOBY-R2 series modules’ switch-off routines can largely vary depending
on the application / network settings and the concurrent module activities.