The CellLocate
®
database is compiled from the position of devices which observed, in the past, a
specific cell or set of cells (historical observations) as follows:
1. Several devices reported their position to the CellLocate
®
server when observing a specific cell
(the As in the picture represent the position of the devices which observed the same cell A)
2. The CellLocate
®
server defines the area of Cell A visibility
3. If a new device reports the observation of Cell A, CellLocate
®
is able to provide the estimated
position from the area of visibility