Integration Manual
Table Of Contents
- Document Information
- Contents
- 1 System description
- 1.1 Overview
- 1.2 Architecture
- 1.3 Pin-out
- 1.4 Operating modes
- 1.5 Power management
- 1.6 System functions
- 1.7 RF connection
- 1.8 (U)SIM interface
- 1.9 Serial communication
- 1.9.1 Serial interfaces configuration
- 1.9.2 Asynchronous serial interface (UART)
- 1.9.2.1 UART features
- 1.9.2.2 UART signal behavior
- 1.9.2.3 UART and power-saving
- 1.9.2.4 UART application circuits
- Providing the full RS-232 functionality (using the complete V.24 link)
- Providing the TxD, RxD, RTS, CTS and DTR lines only (not using the complete V.24 link)
- Providing the TxD, RxD, RTS and CTS lines only (not using the complete V.24 link)
- Providing the TxD and RxD lines only (not using the complete V24 link)
- Additional considerations
- 1.9.3 USB interface
- 1.9.4 SPI interface
- 1.9.5 MUX protocol (3GPP TS 27.010)
- 1.10 DDC (I2C) interface
- 1.11 Audio Interface
- 1.12 General Purpose Input/Output (GPIO)
- 1.13 Reserved pins (RSVD)
- 1.14 Schematic for LISA-U2 module integration
- 1.15 Approvals
- 1.15.1 European Conformance CE mark
- 1.15.2 US Federal Communications Commission notice
- 1.15.3 Innovation, Science, Economic Development Canada notice
- 1.15.4 Australian Regulatory Compliance Mark
- 1.15.5 ICASA Certification
- 1.15.6 KCC Certification
- 1.15.7 ANATEL Certification
- 1.15.8 CCC Certification
- 1.15.9 Giteki Certification
- 2 Design-In
- 3 Features description
- 3.1 Network indication
- 3.2 Antenna detection
- 3.3 Jamming Detection
- 3.4 TCP/IP and UDP/IP
- 3.5 FTP
- 3.6 HTTP
- 3.7 SSL/TLS
- 3.8 Dual stack IPv4/IPv6
- 3.9 AssistNow clients and GNSS integration
- 3.10 Hybrid positioning and CellLocate®
- 3.11 Control Plane Aiding / Location Services (LCS)
- 3.12 Firmware update Over AT (FOAT)
- 3.13 Firmware update Over the Air (FOTA)
- 3.14 In-Band modem (eCall / ERA-GLONASS)
- 3.15 SIM Access Profile (SAP)
- 3.16 Smart Temperature Management
- 3.17 Bearer Independent Protocol
- 3.18 Multi-Level Precedence and Pre-emption Service
- 3.19 Network Friendly Mode
- 3.20 Power saving
- 4 Handling and soldering
- 5 Product Testing
- Appendix
- A Migration from LISA-U1 to LISA-U2 series
- A.1 Checklist for migration
- A.2 Software migration
- A.2.1 Software migration from LISA-U1 series to LISA-U2 series modules
- A.3 Hardware migration
- A.3.1 Hardware migration from LISA-U1 series to LISA-U2 series modules
- A.3.2 Pin-out comparison LISA-U1 series vs. LISA-U2 series
- A.3.3 Layout comparison LISA-U1 series vs. LISA-U2 series
- B Glossary
- Related documents
- Revision history
- Contact
LISA-U2 series - System Integration Manual
UBX-13001118 - R25 Product Testing Page 162 of 182
5 Product Testing
5.1 u-blox in-series production test
u-blox focuses on high quality for its products. All units produced are fully tested. Defective units are
analyzed in detail to improve production quality.
This is achieved with automatic test equipment, which delivers a detailed test report for each unit.
The following measurements are made:
Digital self-test (firmware download, flash firmware verification, IMEI programming)
Measurement of voltages and currents
Adjustment of ADC measurement interfaces
Functional tests (serial interface communication, real time clock, battery charger, temperature
sensor, antenna detection, SIM card communication)
Digital tests (GPIOs, digital interfaces)
Measurement and calibration of RF characteristics in all supported bands (receiver S/N
verification, frequency tuning of reference clock, calibration of transmitter and receiver power
levels)
Verification of RF characteristics after calibration (modulation accuracy, power levels and
spectrum performance are checked to be within tolerances when the calibration parameters are
applied)
Figure 75: Automatic test equipment for module tests