Installation Guide 1175R Refrigerator, 1175WC Wine Captain® and 1175BEV Beverage Center www.U-LineService.com Phone (414) 354-0300 • FAX (414) 354-7905 Service & Parts Tech Lines Phone (800) 779-2547 • FAX (414) 354-5696 OnlineService@U-Line.
1175R, 1175WC and 1175BEV Models Contents Exterior Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Cut-Out Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . Product Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . Door Swing/Clearances Information . . . . . . . . . . . . . . Reversing the Door. . . . . . . . . . . . . . . . . . . . . . . . . . . . . Other Site Requirements . . . . . . . . . . . . . . . . . . . . . . . . .................................
1175R, 1175WC and 1175BEV Models General Precautions 2 Inspect and Plan Use this appliance for its intended purpose only and follow these general precautions along with those listed throughout this guide: You have received a carton containing your 1175R Refrigerator, 1175WC Wine Captain® or 1175BEV Beverage Center with a package inside containing a Use and Care Guide and a Product Registration Card. Complete and mail the Product Registration Card or register online at www.U-LineService.com.
1175R, 1175WC and 1175BEV Models Exterior Cleaning 3 Prepare Site (As Required) Your U-Line product has been designed for either freestanding or built-in installation. When built-in, your unit does not require additional air space for top, sides or rear. However, the front grille must NOT be obstructed and clearance is required for electrical connection in the rear. Black and White Models: • Black and White surfaces may be cleaned with a mild detergent and warm water solution.
1175R, 1175WC and 1175BEV Models Product Dimensions 23-7/16" Including Handle Door Swing/Clearances Information All 1175 units have a zero clearance for the door to open 90° (see Figure 3). Stainless units require a minimum of 2" door clearance to accommodate the handle if the unit is installed next to a wall or similar type of structure. 25-7/16" Including Handle Note: A 1175 BLACK Wine Captain® must be able to have door swing open a minimum of 135°.
1175R, 1175WC and 1175BEV Models Reversing the Door Hinge (1175 Black & White Units Only) Plastic Plug Hole Plastic Plug Hole All units may be left- or right-hand opening (All Stainless Steel and 1175 Beverage Center units cannot be fieldreversed). Black and White 1175 Units Screw Left Side Door Swing Right Side Door Swing To reverse the door on Black or White 1175 models: 1. Remove the grille (two screws). Figure 6 Right Side Hinge Invert Screw Invert Hinge ULIN_0106_A 5.
1175R, 1175WC and 1175BEV Models Other Site Requirements Power Supply 1 The unit requires a grounded and polarized 115 VAC, 60 Hz, 15A circuit (normal household current). See Electrical Specifications on Page 11. Environmental Requirements Figure 9 Many U-Line models are designed to operate in harsh outdoor/marine environments. Special considerations include the following: ULIN_0109_A (1175 REFRIGERATOR requirements) 9.
1175R, 1175WC and 1175BEV Models Side-By-Side Installation Instructions 4 Prepare/Install Door Panel or Prepare Racks For a complete refreshment center, install two of the following 1175 series units side by side: 1175R, 1175WC or a 1175 BEV Center. Note that each Side-By-Side Installation will be different. Three types of custom treatments may be involved in your installation: • Black and White 1175R Refrigerators will accept a Custom 1/4" Thick Insert to harmonize with or accent the surrounding decor.
1175R, 1175WC and 1175BEV Models CAUTION To prevent permanent damage to the inner liner of the Beverage Center and the Wine Captain, the wine rack wood trim MUST be removed from the unit for staining and/or finishing. Allow stain/finish to dry thoroughly (at least 24 hours per coat) in accordance with the stain/finish manufacturer’s instructions prior to re-installing the wood trim inside the cabinet of the Beverage Centeror the Wine Captain.
1175R, 1175WC and 1175BEV Models Wood Trim Finishing 6. Remove all dust from the wood, and apply one coat of Minwax® Polycrylic® Protective Finish using a synthetic bristle brush to the wood. This finish should be applied in a thin coat following the direction of the grain. Apply the finish to the back and sides of the wood first, and allow it to dry for two hours. Apply the finish to the front side of the wood next, and allow it to dry for two hours. Sand with very fine 220 grit sandpaper.
75R, 1175WC and 1175BEV Models 5 Adjust Door 6 Prepare Power Supply Checking Door Alignment Electrical Specifications The unit’s door is aligned at the factory before shipment. However, its alignment could have been disturbed during shipment or during door panel installation. CAUTION Electrical installation must observe all state and local codes. This unit requires connection to a grounded (threeprong), polarized receptacle that has been placed by a qualified electrician.
1175R, 1175WC and 1175BEV Models 7 Level the Unit 8 Install the Unit Leveling Information Installation of the 1175R/1175WC/ 1175BEV Note: It is recommended that the unit is level. 1. Use a level to check the levelness of the unit from front to back and from side to side. Level should be placed along top edge and side edge as shown (see Figure 18). 1. Plug in the power cord. 2. Gently push the unit into position. Be careful not to entangle the electrical cord. 3.
9 Start-Up for the First Time Initial Start-Up The unit is shipped with the control preset. No other adjustments should be necessary at this time. For information about Adjusting the Controller, see the Use and Care Guide. Start-Up Troubleshooting Q: Problem Who to Call Service Information If the need for service arises, call the U-Line Customer Care Center directly @ 800-779-2547. To ensure accurate assistance, please have your Model Number and Serial Number and an explanation of the problem.