Use and Care Guide Dual Zone Models Wine Captain® Models: 2275ZWC & 2275ZWCOL 2275ZWC 2275ZWCOL
Introduction Congratulations on your purchase of a U-Line refrigeration product. A pioneer in the field for more than 40 years, U-Line Corporation is the world’s number one manufacturer of built-in, under-counter, specialty refrigeration and ice making products. U-Line dedicates 100% of its research and development to these products. The result: U-Line technology consistently leads the market with innovation, design, depth of product line and performance.
TABLE OF CONTENTS Introduction .................................................................................................. Inside Front Cover Warranty Registration .................................................................................. Inside Front Cover Please Record Your Model Information ...................................................... Inside Front Cover 1-Safety Precautions ...........................................................................................................
WARNING 1 SAFETY PRECAUTIONS SHOCK HAZARD - Electrical Grounding Required. IMPORTANT PLEASE READ all instructions completely before attempting to install operate or service your unit. • Proper installation procedures must be followed if this unit is being initially installed, or is moved to a new location after being in service.
b. Door full overlay wood frames are customer provided, and not supplied by U-Line. 2 PRODUCT FEATURES Échelon Dual Zone Wine Captain Wine Captain Models 2275ZWC and 2275ZWCOL feature specially designed wine racks that allow for the proper horizontal storage of wine. The corks remain moist, which keeps air from entering the bottles.
5 REPLACEMENT PARTS When you need replacement parts, always request that genuine U-Line replacements be used. U-Line products have been designed and engineered using components that work efficiently, and provide superior service life and performance. The use of aftermarket parts or components may affect the safety, operation, performance or durability of your product, and may also void its warranty.
Dual Temperature Zones Your unit has been designed to provide two temperature zones (top and bottom) in the cabinet. Each zone can be adjusted within the 4 following temperature ranges: Note: These are product temperatures, not air temperatures.
DISPLAY OFF MODE A DISPLAY OFF mode is available through the control panel. This mode allows you to control whether the displays (Figure 7) will be ON or OFF whenever the door is closed. The icon touch sequence that follows will switch between both modes: 1. Touch and hold the left display WARMER icon, and within five seconds press the POWER icon three times (Figure 7). 2. The displays will be either visible or dark when the door is closed. 3. To return to the previous mode, repeat Step 1.
Wine Selections Suggestions 9 PRODUCT DISPOSAL If the unit is being removed from service for disposal, check and obey all Federal, State and/or Local regulations regarding the disposal and recycling of refrigeration appliances, and follow these steps completely: 1. Remove all consumable contents from the unit. 2. Disconnect power to the unit and unplug the power cord from its outlet.
GUIDE TO COMMON STYLES OF WINE Red Wines Full-Bodied Dry California French Italian Zinfandel, Cabernet Rhone, Chateauneuf-du-Pape Barbaresco, Barolo Medium-Bodied Dry California French Pinot Noir Bordeaux, Burgundy Light-Bodied Dry French Italian Beaujolais Chianti, Bardolino Full-Bodied Dry California French Chardonnay Montrachet, Meursault Puligny-Montrachet Medium-Bodied Dry California French Sauvignon-Blanc Pouilly-Fuisse, Sancerre, Vouvray, Graves Light-Bodied Dry French Chablis, Musca
MAINTENANCE & CLEANING Proper maintenance of your U-Line product will ensure efficiency, top performance and long life. The maintenance intervals listed are based on normal conditions. You may want to shorten the intervals if you have pets or other special considerations. Exterior Cleaning (As Required) opened in a high heat or high humidity location. If this frost pattern does not clear within 24 hours, your unit will require manual defrosting.
Condenser Cleaning Leveling INTERVAL - EVERY THREE MONTHS To maintain operational efficiency, keep the front grille free of dust and lint and clean the condenser every three months. Depending on environmental conditions, more or less frequent cleaning may be necessary. WARNING Disconnect electric power to the unit before cleaning the condenser. To remove and replace the grille for access to the condenser fins, follow this procedure: Screws ULIN_1014_A Figure 12.
Door Alignment Check and Adjustment (Figure 16). Repeat until top edge of door is parallel with top of cabinet and tighten screws securely. IMPORTANT Slotted Mounting Holes When properly aligned: • The door will not be flush with the top of the cabinet. The top edge of the door will be 1/8 in. (3.175 mm) below the cabinet top. • The door gasket will be firmly in contact with the perimeter of the cabinet and not pinched on the hinge side of the door. The following procedure will correct for up to 1/4 in.
Light Bulb Replacement IMPORTANT To replace the light bulb in your U-Line unit: Do not remove the track side rails from the cabinet. To insert a rack in the cabinet: Light Housing Lens 1. Align the left and right rack channels with the tracks in the cabinet, and ensuring an even track engagement on both sides, gently push the rack into the cabinet until it stops. Tab ULIN_0001_A Figure 18. Light Housing Lens 1.
4. Allow stain to dry for a minimum of three hours before applying the final finish. 5. If desired, sand the wood with very fine sandpaper to smooth the surface after the staining process. 6. Remove all dust from the wood, and apply one coat of Minwax® Polycrylic® Protective Finish using a synthetic bristle brush to the wood. This finish should be applied in a thin coat following the direction of the grain. Apply the finish to the back and sides of the wood first, and allow it to dry for two hours.
13 TROUBLESHOOTING GUIDE DANGER ELECTROCUTION HAZARD Never attempt to repair or perform maintenance on the unit until the main electrical power has been disconnected. PROBLEM POSSIBLE CAUSE REMEDY Unit does not operate and electronic display is blank. No electrical supply Plug unit in or check circuit breaker. No interior light Loose or burned out bulb Tighten or replace bulb (See MAINTENANCE; LIGHT BULB REPLACEMENT). Electronic display is blank and interior light is OFF with door OPEN.
14 ELECTRONIC QUICK CONTROL GUIDE Task Turn ON/OFF Adjust Set-Point Temperature Touch Hold 10 seconds Touch and release desired zone warmer icon then Touch and release the light icon View Actual Temperature Hold 5 seconds for desired zone Change °F-°C Hold Blackout Mode Touch Display Release when unit beeps. or Zone range is displayed after first touch, set-point displayed after touching LIGHT icon. Set-point saved after 5 seconds of inactivity.
This page intentionally left blank.
U-Line Corporation Limited Warranty U-Line Corporation warrants each U-Line product to be free from defects in materials and workmanship for a period of one year from the date of purchase; and warrants the sealed system (consisting of the compressor, the condenser, the evaporator, the hot gas bypass valve, the dryer and the connecting tubing) in each U-Line product to be free from defects in materials and workmanship for a period of five years from the date of purchase.
For General Inquiries: P.O. Box 245040 Milwaukee, Wisconsin 53224-9540 U.S.A. Phone (800) 779-2547 FAX (414) 354-5696 www.U-Line.com For Service and Parts Assistance: Phone (800) 779-2547 (414) 354-0300 FAX (414) 354-5696 Email: OnLineService@U-Line.com www.U-LineService.com E-mail: OnlineParts@u-line.com For more than four decades, U-Line has distinguished itself as the leader in built-in under-counter ice making, refrigeration and wine storage appliances.