A D A S E R I E S Use and Care Guide Ice Maker Model: ADA15IM ADA15IM
ADA SERIES Introduction Congratulations on your purchase of a U-Line refrigeration product. U-Line Corporation, a pioneer in the appliance industry for more than 40 years, is the world’s number one manufacturer of built-in, undercounter, specialty refrigeration and ice making products. U-Line dedicates 100% of its research and development to these products. U-Line technology consistently leads the market with innovation, design, depth of product line and performance.
ADA SERIES b 1 Table of Contents ADA15IM Introduction .................................................................................................. Inside Front Cover Warranty Registration .......................................................................... Inside Front Cover Please Record Your Model Information .............................................. Inside Front Cover Table of Contents ......................................................................................................
ADA SERIES DANGER 2 Safety Precautions IMPORTANT PLEASE READ all instructions completely before attempting to install, operate, or service your unit. • Proper installation procedures must be followed if this unit is being initially installed, or is moved to a new location after being in service. An INSTALLATION GUIDE for your unit, providing complete installation information is available from U-Line Corporation directly, and must be consulted before any installation is begun.
ADA SERIES 3 Product Features 4 Operation Model ADA15IM Ice Maker The ADA15IM Ice Maker will produce and store up to 25 lbs (11.3 kg) of ice per day. It conserves on water, using only 2-3/4 gallons (10.4 L) to produce approximately 22 lbs (10 kg) of ice, and features a clear removable ice bucket. Manual defrosting will be occasionally required.
ADA SERIES WARNING C OL NEVER use an ice pick, knife or other sharp instrument to separate cubes. Shake the ice bucket instead. DE R During periods of limited usage or high ambient temperatures, it is common for cubes to fuse together. Shake the bucket to break apart cubes. If the ice maker is not used regularly, the ice bucket should be emptied periodically to ensure fresh cubes. ULIN_0131_A Figure 2 2.
ADA SERIES Outdoor, Marine and RV Usage 7. Disconnect the power cord from its outlet, and leave it disconnected until the unit is returned to service. Some U-Line models are designed to operate in outdoor, marine and RV environments. For best performance, keep the unit out of direct sunlight. 8. Clean and dry the interior of the cabinet (See CLEANING AND MAINTENANCE: GENERAL CLEANING).
ADA SERIES 5 Cleaning and Maintenance General Cleaning Exterior Cleaning (As Required) Black and White Models: • Surfaces may be cleaned with a mild detergent and warm water solution. Do not use solvent-based or abrasive cleaners. Use a soft sponge and rinse with clean water. Wipe with a soft, clean towel to prevent water spotting. Stainless Steel Models: • Stainless steel surfaces and components can discolor when exposed to chlorine gas, pool chemicals, salt water or cleaners with bleach.
ADA SERIES Maintenance To defrost: Proper maintenance of your U-Line product will ensure efficiency, top performance and long life. The maintenance intervals listed are based on normal conditions. You may want to shorten the intervals if you have pets or other special considerations. 1. Turn unit off. Defrosting 4. If you would like, place warm water inside ice bucket. Then place ice bucket back into unit and close door. Manual Defrost Models - Every Two Months (Minimum) 2.
ADA SERIES Ice Maker Maintenance 3. Turn the adjusting screw toward the minus (-) sign (clockwise) for smaller cubes or toward the plus (+) sign (counterclockwise) for larger cubes. Ice Cube Thickness Adjustment Interval - As Required On ice maker equipped models, the cube size may be adjusted by changing the amount of water injected into the ice maker assembly as follows: 4. Install the ice maker assembly cover. IMPORTANT Use only genuine U-Line replacement parts.
ADA SERIES Door Alignment Check and Adjustment Door Reversal To reverse the door, perform the following: IMPORTANT Properly aligned, the door’s gasket should be firmly in contact with the cabinet all the way around the door (no gaps). Carefully examine the door’s gasket to assure that it is firmly in contact with the cabinet. Also make sure the door gasket is not pinched on the hinge side of the door. 1. Remove the grille (two screws). ULIN_0143_A Figure 10 2.
ADA SERIES 1 ULIN_0109_A Figure 14 7. Relocate plastic spacer/bushing (Figure 15) on bottom of door to opposite side, and place door on bottom hinge pin. Clean out bushing hole in door bottom with a screwdriver if necessary. ULIN_0122_A Figure 12 5. Remove screws on opposite side of cabinet (Figure 13). Note that there may be a nut behind one or both screws on either side.
ADA SERIES . 6 Service Before Calling for Service If your U-Line product appears to be malfunctioning, read through the OPERATION section of this guide to ensure that the function of all controls are clearly understood. If the malfunction persists, the TROUBLESHOOTING GUIDE in this guide will assist you in quickly identifying common problems, and provide information on possible causes and remedies. Most often, this will resolve the problem without the need to call for service.
ADA SERIES Troubleshooting Guide DANGER ELECTROCUTION HAZARD Never attempt to repair or perform maintenance on the unit until the main electrical power has been disconnected. Troubleshooting - What to check when problems occur: PROBLEM POSSIBLE CAUSE REMEDY The unit frosts up. High ambient temperatures or humidity Defrost unit manually (See MAINTENANCE; DEFROSTING). Unit is a manual defrost unit. Model BI2115 is a manual defrost unit (See MAINTENANCE; DEFROSTING).
ADA SERIES U-Line Corporation Limited Warranty 1. U-Line Corporation ("U-Line") warrants each U-Line product to be free from defects in materials and workmanship for a period of one year from the date of purchase. U-Line further warrants the sealed system (consisting of the compressor, the condenser, the evaporator, the hot gas bypass valve, the dryer and the connecting tube) in each U-Line product to be free from defects in materials and workmanship for a period of five years from the date of purchase. 2.
For General Inquiries: U-Line Coporation P.O. Box 245040 Milwaukee, Wisconsin 53224-9540 U.S.A. Phone (414) 354-0300 FAX (414) 354-7905 Email: sales@u-line.com www.u-line.com A D A S E R I E S For Service Assistance: Phone (800) 779-2547 FAX (414) 354-5696 Email: onlineservice@u-line.com www.u-lineservice.com For Parts Assistance: E-mail: onlineparts@u-line.