Installation guide

11/2006 7 www.U-LineService.com
CO1175 — Ice Maker/Refrigerator
Water Supply
The unit requires a 1/4-inch OD water supply line and a
shutoff valve. For more information see Page 9.
Environmental Requirements
The surrounding air temperature must be at least 50°F
(10°C) but must not exceed 110°F (40°C). Units may be
installed outdoors in a covered area. The unit must not be
located near heat-generating equipment or in direct
sunlight.
Side-By-Side Installation
Instructions
For a complete refreshment center, install two of the
following 1175 series units side by side: CO1175, 1175R
Refrigerator or 1175WC Wine Captain
®
. Note that each
Side-By-Side Installation will be different.
Cut-out width for a side-by-side installation is the total
of the widths listed under Cut-Out Dimensions in each
unit’s Installation Guide.
For example:
Placing a CO1175 next to another 1175 series unit
would require a cut-out width of:
24-3/16" + 24-3/16" = 48-3/8"
No trim kit is required. However, 1/4-inch space needs to
be maintained
between the units to ensure
unobstructed door swing.
Units must operate from separate, properly grounded
electrical receptacles placed according to each units
Electrical Specifications.
7"
4"
34-1/4"
to
35-1/8"
1/4" Space
Between
Appliances
24"
Figure 11
Typical Side-By-Side Cut-Out