Installation guide
11/2006 7 www.U-LineService.com
CO1175 — Ice Maker/Refrigerator
Water Supply
The unit requires a 1/4-inch OD water supply line and a 
shutoff valve. For more information see Page 9.
Environmental Requirements
The surrounding air temperature must be at least 50°F 
(10°C) but must not exceed 110°F (40°C). Units may be 
installed outdoors in a covered area. The unit must not be 
located near heat-generating equipment or in direct 
sunlight.
Side-By-Side Installation 
Instructions
For a complete refreshment center, install two of the 
following 1175 series units side by side: CO1175, 1175R 
Refrigerator or 1175WC Wine Captain
®
. Note that each 
Side-By-Side Installation will be different.
• Cut-out width for a side-by-side installation is the total 
of the widths listed under Cut-Out Dimensions in each 
unit’s Installation Guide. 
For example:
Placing a CO1175 next to another 1175 series unit 
would require a cut-out width of:
24-3/16" + 24-3/16" = 48-3/8"
•
No trim kit is required. However, 1/4-inch space needs to 
be maintained 
between the units to ensure 
unobstructed door swing.
• Units must operate from separate, properly grounded 
electrical receptacles placed according to each unit’s 
Electrical Specifications.
7"
4"
34-1/4"
to
35-1/8"
1/4" Space
Between
Appliances
24"
Figure 11
Typical Side-By-Side Cut-Out