Installation guide
11/2006 9 www.U-LineService.com
CO1175 — Ice Maker/Refrigerator
Checking Door Alignment
The unit’s door is aligned at the factory before shipment. 
However, its alignment could have been disturbed during 
shipment or during door panel installation.
IMPORTANT
Properly aligned, the door's gasket should be firmly in 
contact with the cabinet all the way around the door (no 
gaps).
1. Carefully examine the door's gasket to assure that it is 
firmly in contact with the cabinet.
Note: When inspecting door alignment, make sure the 
light switch bracket makes contact with the light switch 
plunger. Also make sure the door gasket is not pinched on 
the hinge side of the door.
2. If the door is properly aligned, go on to 
6 Prepare 
Plumbing
. If it is not, use the following procedure.
Adjusting Door Alignment
1. Loosen (do not remove) 
top and bottom hinge 
screws. See Figure 15.
2. Align door squarely with 
cabinet. Make sure gasket 
is firmly in contact with 
cabinet all the way around 
the door (no gaps).
3. Tighten bottom hinge 
screws.
4. Tighten top hinge screws. 
Go on to 
6 Prepare 
Plumbing
.
CAUTION
Plumbing installation must observe all state and local 
codes. All water connections MUST BE made by a licensed/
qualified plumbing contractor. Failure to follow 
recommendations and instructions may result in damage 
and/or harm.
WARNING
To prevent accidental electrocution, make certain 
that the floor surfaces surrounding the unit are 
dry whenever power is removed from, or applied 
to, the unit.
Water Supply Connection
When connecting the water supply, follow these 
guidelines:
• Review the local plumbing codes before you install the 
unit.
• Connect to the cold water supply.
• The water pressure should be between 20 and 120 psi.
• Install a shutoff valve in the 1/4 inch OD water supply 
line.
• Connect sufficient tubing to the unit so that tubing 
may be looped, allowing the unit to be removed for 
cleaning and servicing (see Figure 18). However, make 
certain that the tubing is not pinched or damaged 
during installation.
• U-Line recommends the use of copper tubing for 
installation.
To connect to water supply:
1. Install the 1/4 inch OD copper water line from the 
main water source.
5 Adjust Door
Figure 15