QUICK START GUIDE Combo® Models • 115 V / 60 Hz
QUICK START GUIDE u-line.com WELCOME TO U-LINE Congratulations on your U-Line purchase. Your product comes from a company with over five decades of premium modular ice making, refrigeration, and wine preservation experience. U-Line continues to be the American leader, delivering versatility and flexibility for multiple applications including residential, light commercial, outdoor and marine use.
QUICK START GUIDE u-line.com This Quick Start Guide covers the basics of installation and general use of your product. For more details, see the complete User Guide & Service Manual on u-line.com. Contents 1. Safety and Warning 1. Environmental Requirements 2. Electrical 2. Water Hookup 4. Door Swing 5. Door Adjustments 7. General Installation 8. Integrated Panel Installation 11. Control Operation 11. First Use 12. Defrost 12. Ice 13.
QUICK START START GUIDE GUIDE u-line.com u-line.com Safety and Warning Environmental Requirements NOTICE This model is intended for indoor/interior applications only and is not to be used in installations that are open/ Please read all instructions before installing, exposed to natural elements. operating, or servicing the appliance. This unit is designed to operate between 50°F (10°C) and Use this appliance for its intended purpose only and follow 100°F (38°C).
QUICK START START GUIDE GUIDE u-line.com u-line.com Electrical Water Hookup PREPARE PLUMBING ! WARNING The water valve uses a standard 1/4" (6.35 mm) compression fitting. U-Line recommends using accessory SHOCK HAZARD — Electrical Grounding water hook up kit – part # WATERHOOKUP. The kit Required. Never attempt to repair or perform includes a 10' (3 m) braided flexible water supply line and maintenance on the unit until the electricity has a brass hose fitting. When using a 1/4" (6.35 mm) O.D.
QUICK START START GUIDE GUIDE QUICK u-line.com u-line.com 3. Locate water valve inlet. ! CAUTION Do not use any plastic water supply line. The line is under pressure at all times. Plastic may crack or rupture with age and cause damage to your home. Do not use tape or joint compound when attaching a braided flexible water supply line that includes a rubber gasket. The gasket provides an adequate seal – other materials could cause blockage of the valve. 4.
QUICK START START GUIDE GUIDE QUICK u-line.com u-line.com 9. Install retaining clip. Integrated models require 1/4" (6 mm) clearance if installed next to a wall. Allow for additional space for any knobs or pulls installed on the integrated panel/frame. BI95/BI98 All units have a zero clearance for the door to open 90°. U-Line recommends a minimum door clearance of 1/4" (6 mm) to accommodate the handle if the unit is installed next to a wall. 1/4" Min.
QUICK QUICK START START GUIDE GUIDE u-line.com u-line.com Door Adjustments DOOR ALIGNMENT AND ADJUSTMENT Align and adjust the door if it is not level or is not sealing properly. If the door is not sealed, the unit may not cool properly, or excessive frost may form in the interior. Properly aligned, the door’s gasket should be firmly in contact with the cabinet all the way around the door (no gaps). Carefully examine the door’s gasket to ensure that it is firmly in contact with the cabinet.
QUICK QUICK START START GUIDE GUIDE u-line.com u-line.com 3. Remove door by tilting forward and lifting door off 3. Rotate gasket 180°, aligning notch with plunger bottom hinge. Retain shoulder washers; they will be bracket and pressing firmly into the gasket channel reused. starting at the corners. 4. Remove four screws from hinge holes on the opposite 4. Rotate door 180° to reverse. side. Reinstall into holes where the hinge was removed. Take care not to scratch cabinet.
QUICK START START GUIDE GUIDE u-line.com u-line.com General Installation 1. Use a level to confirm the unit is level. Level should MARINE AND BI95/BI98 SERIES be placed along top LEVELING INFORMATION edge and side edge as shown. NOTICE Because these units do not have leveling legs, it is extremely important that they sit on a level 1 surface. If they are not level, the ice mold will not fill evenly. Use a level to confirm 2.
QUICK START START GUIDE GUIDE u-line.com u-line.com 3. Re-check the leveling, from front to back and side to 2. Pull door gasket out of groove side. Make any necessary adjustments. The unit’s top (top edge of door only). Start in surface should be approximately 1/8" (3 mm) below the middle and pull outward, the countertop. moving toward the edge. This may take some force. 4. Install the anti-tip bracket. 5.
QUICK START START GUIDE GUIDE u-line.com u-line.com CO1224F Due to differences in floor construction or 1. Fully open door/drawer. surrounding cabinetry, the panel may not sit flush with the top of the door/drawer. 2. Starting at corner, pull gasket away from door/ Panel Door drawer. 3. Continue to pull gasket free from gasket channel. 9. Secure integrated panel to door/drawer 4. Upon removal, lay gasket Bar Clamp using clamps. A down on a flat surface. robust tape may also be used. U-Line 5.
QUICK QUICK START START GUIDE GUIDE u-line.com u-line.com 13.Be sure the screws force their way past the opening on the gasket channel and sit flush against the bottom of the channel. Integrated Panel Integrated Panel 14.Remove clamps from door/drawer. If panel requires additional adjustment after removing clamps, slightly loosen each screw and adjust panel as necessary. Tighten screws upon completion. Starting at the corners, re-install the gasket into the gasket channel in the frame.
QUICK START START GUIDE GUIDE QUICK u-line.com u-line.com Control Operation Not Light Power Used LED Up Down CONTROL FUNCTION GUIDE FUNCTION COMMAND DISPLAY/OPTIONS ON/OFF Press and release Unit will immediately turn ON or OFF.
QUICK QUICK START START GUIDE GUIDE u-line.com u-line.com Defrost First Use To turn off ice production: Raise the bin arm into All U-Line controls are presetdefrost, at the factory. Initial startup This unit requires manual periodically. temperature for ice storage. an upright and locked position. The unit will preserve requires no adjustments. Inspect the interior walls for frost build up every 3 - 4 weeks. Defrost your unit when 1/4” of frost builds up NOTICE on the interior walls.
QUICK START GUIDE QUICK START GUIDE u-line.com u-line.com Sabbath Mode 1 2 3 4 5 6 7 This unit is Star-K certified and offers a Sabbath mode. Sabbath mode disables system responses to user initiated activities and all external functions, including lighting, display and audible alarms. The unit will still maintain internal temperatures and set points. View a full list of Star-K certified U-Line units at www.star-k.org. To enable Sabbath Mode: 1.
U-Line Corporation (U-Line) Limited Warranty One Year Limited Warranty For one year from the date of original purchase, this warranty covers all parts and labor to repair or replace any part of the product that proves to be defective in materials or workmanship. For products installed and used for normal residential use, material cosmetic defects are included in this warranty, with coverage limited to 60 days from the date of original purchase.