QUICK START GUIDE Modular 3000 Series • 3018 CLR • 115 V / 60 Hz
QUICK START GUIDE u-line.com WELCOME TO U-LINE Congratulations on your U-Line purchase. Your product comes from a company with over five decades and three generations of premium modular ice making, refrigeration, and wine preservation experience. U-Line continues to be the American leader, delivering versatility and flexibility for multiple applications including residential, light commercial, outdoor and marine use.
QUICK START GUIDE u-line.com This Quick Start Guide covers the basics of installation and general use of your product. For more details, see the complete User Guide & Service Manual on u-line.com.
QUICK START GUIDE u-line.com Safety and Warning Environmental Requirements NOTICE This model is intended for indoor/interior applications only and is not to be used in installations that are open/ Please read all instructions before installing, exposed to natural elements. operating, or servicing the appliance. This unit is designed to operate between 50°F (10°C) and Use this appliance for its intended purpose only and follow 100°F (38°C).
QUICK START GUIDE u-line.com Electrical ! WARNING SHOCK HAZARD — Electrical Grounding Required. Never attempt to repair or perform maintenance on the unit until the electricity has been disconnected. Never remove the round grounding prong from the plug and never use a two-prong grounding adapter. Altering, cutting or removing power cord, removing power plug, or direct wiring can cause serious injury, fire, loss of property and/or life, and will void the warranty.
QUICK START GUIDE u-line.com Water Hookup ! CAUTION PREPARE PLUMBING The water valve uses a standard 1/4" (6.35 mm) Do not use any plastic water supply line. The line compression fitting. A 10' (3 m) braided flexible water is under pressure at all times. Plastic may crack supply line is included with the unit. or rupture with age and cause damage to your home.
QUICK START GUIDE u-line.com 8. Install retaining clip. 3. Locate water valve in the front of the unit and thread water supply line through. Route the water supply line through the unit so it does not come into contact with any internal components other than the solenoid valve. Normal operation creates some vibration. A water supply line contacting an internal component or cabinet wall can cause excessive noise during operation or damage to the line. 4.
QUICK START GUIDE u-line.com Drain GRAVITY DRAIN Model numbers including “-00” or “-07” do not include a factory installed drain pump. Normal Proper Drain Model numbers including “-40” or “-47” include a factory installed drain pump. With Trap Poor Drainage, Water Will Back Up DRAIN CONNECTION ! CAUTION With Trap and Vent Proper Drain If your U-Line unit did not come with a factory installed drain pump you must use a gravity A gravity drain may be used if: style drain connection.
QUICK START GUIDE u-line.com FACTORY INSTALLED DRAIN PUMP Y-Branch Tailpiece P60 Pump Required If your drain line will run up to a stand pipe, disposal or Air Gap (Optional Hook-Up) spigot assembly, or does not otherwise meet the requirements for a gravity drain, you may have ordered a pre-installed U-Line P60 drain pump. Waste If you need to install a P60 drain pump into your unit, see 6KXW 2ɞ Valve DRAIN PUMP section in the User Manual.
QUICK START GUIDE u-line.com Door Swing Wall For Integrated models that are installed adjacent to a wall, 1/4" (6 mm) 1/4" (6 mm) clearance is recommended from wall on hinge side to allow the door to open 90°. Allow for additional space for any knobs or pulls installed on the integrated panel/frame. Stainless Steel models that are installed adjacent to a wall require 2-1/4" (57 mm) door clearance on hinge side to allow for door handle.
QUICK START GUIDE u-line.com General Installation INSTALLATION 1. Plug in the power/electrical cord. 1. Use a level to confirm the unit is level. Level 2. Gently push the unit into position. Be careful not to should be placed along top edge and side entangle the cord or water and drain lines. 1 edge as shown. 3. Re-check the leveling, from front to back and side to side. Make any necessary adjustments. The unit’s top 2.
QUICK START GUIDE u-line.com 10.Ensure the screws sit flush against the bottom of the NOTICE channel. Due to differences in floor construction or surrounding cabinetry, the panel may not sit flush with the top of the door. 6. Secure integrated panel to door using Bar Clamp Integrated Panel Integrated Panel clamps. A robust tape may also be 11.Remove clamps from door. used. U-Line recommends the use of bar clamps to secure the panel to the door.
QUICK START GUIDE u-line.
QUICK START GUIDE u-line.com The ice cube thickness is factory set for best overall performance. The factory setting “0” is designed to THINNER BRIDGE THICKER BRIDGE maintain an ice bridge of approximately 1/16" to 1/8" DEEPER DIMPLE (1.6 mm to 3.2 mm) under normal conditions, resulting in SHALLOWER DIMPLE a dimple of approximately 1/4" to 1/2" (6.4 mm to 12.7 mm) in depth. A fuller cube with less of a dimple results in a thicker ice bridge.
QUICK START GUIDE u-line.com L Sabbath Mode 1 2 3 4 5 6 7 Up Select Down U-Line Clear Ice Machine models are Star-K certified and can be used during the Sabbath. View a full list of Star-K certified U-Line units at www.star-k.org. To prepare the unit for the Sabbath: 1. Press and hold the until the unit turns off. 2. No new ice will form when the unit is off, but previously made ice will still be accessible/present for over 24 hours.
U-Line Corporation (U-Line) Limited Warranty One Year Limited Warranty For one year from the date of original purchase, this U-Line product warranty covers all parts and labor to repair or replace any part of the product that proves to be defective in materials or workmanship. For products installed and used for normal residential use, material cosmetic defects are included in this warranty, with coverage limited to 60 days from the date of original purchase.