Brochure

*Add 1-1/2” For Water Line Clearance
25-1/16"
(637 mm)
13-15/16"
(354 mm)
17" (432 mm) *
8-15/16"
(227 mm)
Model BI95
Amps: Running 
Control Type 
Defrost Type Manual
Dimensions: Product Depth 
Dimensions: Product Height 
Dimensions: Product Width 
 na
ENERGY STAR na
Ice Production Per Day 23 lbs
Ice Storage 12 lbs
Product Weight: Max 53 lbs
Refrigerant Type R134a
 No
No additional clearance around sides, top or rear of


This unit requires a grounded a polarized 115 VAC, 60 Hz, 15 A power

Cut-Out
Height
25-1/8"
(638 mm)
Filler Panel (Not Provided by U-Line) –
Needed to Attach Mounting Flange on Unit
18-1/2"
(470 mm)
Minimum
Preferred location
for water line and
eletrical outlet is in
adjacent cabinet.
14-1/4"
(362 mm)
Cut Out Width
3/4"
(19 mm)
Minimum Flange
Mounting Area
3/4"
(19 mm)
Minimum Flange
Mounting Area
5/8"
(16 mm)
4"
(102 mm)
7"
(178 mm)
111
Bi95
ADA Series14” Crescent Ice Maker
dimensions specifications
eLectRicaL ReQUiRements
caBinet cUt-oUt
instaLL ation notes
Please visit u-line.com to view this model’s User Guide.
All specications are subject to change without notice.
Dimensions shown apply to all nishes.