User Guide & Service Manual (Integrated Frame)
USER GUIDE
 Control Operation - Service 8
u-line.com
SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE
The Fan Delay menu option allows the modification of fan 
run times during and after a cooling cycle. In order to 
allow time for the evaporator to properly cool, the 
evaporator fan is delayed from starting with the cooling 
cycle for a given amount of time. In order to remove as 
much warmth as possible from the cabinet the evaporator 
fan will continue to run at the end of the cooling cycle for 
a given amount of time. 
Fan Delay On=
“Fan Delay On” is the amount of time in minutes the fan 
will be delayed from starting from the beginning of a 
cooling cycle. 
Fan Delay Off=
“Fan Delay Off” is the amount of time in minutes the fan 
will continue to run at the end of a cooling cycle.
To access Fan Delay
1. Press   to select “Fan Delay”.
2. Press .
To change fan delay
3. Press   to select either “Fan Delay On” or “Fan Delay 
Off” and press  . The chosen option will begin to 
flash. 
4. Press   or   to change settings.
5. Press   to confirm.
To exit Fan Delay, press   to select “Return to Menu” 
and press   to confirm.
Showroom Mode
Showroom displays a number of features and allows the 
unit to be powered on without running the cooling system. 
To toggle showroom mode
1. Press   to select “Showroom Mode”.
2. Press .
3. Press   to select “Off” and press  . “Off” will begin to 
flash.
4. Press   or   to toggle between off and on.
5. Press   to confirm.
If set to “on” showroom mode will begin immediately. To 
exit showroom mode press   and hold for 5 seconds and 
release. The display will show a countdown to switching 
the unit off. Press   again and the unit will immediately 
switch on retaining the presets from before it entered 
showroom mode.
To exit the showroom mode menu, press   to select 
“Return to Menu” and press   to confirm.
Up
Select
Down
RETURN TO MENU
SHOWROOM MODE
OFF
65










