User Guide & Service Manual

USER GUIDE
u-line.com
Quick Guide
GENERAL BOARD FUNCTIONS
PROGRAM AN UNPROGRAMMED BOARD
THERMISTOR RESISTANCE DATA
ON/OFF Press power button and unit will turn on or o.
Light Hold the Down key and Light key. Adjust between settings 0, 1, or 2. Tap Light key to save.
Change F/C Hold Up and Down buttons for 5 seconds.
Showroom Mode Hold Light and Power buttons for 5 seconds to enter. Unplug to exit. The degree symbol will ash
while in Showroom mode.
Sabbath Mode Hold Light button for 5 seconds to enter. Tap Light button to exit.
Service Mode Hold down Hidden button (U-Line logo) to enter. Scroll through options with Up and Down buttons.
3 Hour Shuto Mode
(Silent Mode)
Hold Down button and Power button for 5 seconds to enter Silent Mode on select models.
Clean Mode Hold the Clean button for 5 seconds to enter Clean mode on select models.
1. Plug the unit into appropriate power source as dened
on the data plate.
2. Once the double dashes appear, hold the hidden
U-Line button for 3-5 seconds.
3. When 00 appears, use the up and down buttons to
select the appropriate model number.
4. Press the light bulb button once.
5. The display will blink, and then will appear as the
programmed display.
Tosetaprogrammedboardtothecorrectmodel,see
“Programming the Unit to Correct Model Number” in
the“ControlOperation-Service”section.
TEMP(F) TEMP(C)
Nominal
Resistance
(OHMS)*
-40 -40 169157
-31 -35 121795
-22 -30 88766
-13 -25 65333
-4 -20 48614
5 -15 36503
14 -10 27681
23 -5 21166
32 0 16330
41 5 12696
50 10 9951
59 15 7855
68 20 6246
77 25 5000
86 30 4029
95 35 3266
104 40 2665
113 45 2186
122 50 1803
131 55 1495
140 60 1247
149 65 1044
158 70 879
167 75 743
176 80 631
*
+ 5%
29