QUICK START GUIDE DISPENSERS • HDE215 (115v) • 2 Tap Coffee 30636_C
QUICK START GUIDE USER GUIDE u-line.com WELCOME TO U-LINE Congratulations on your U-Line purchase. Your product comes from a company with over five decades of premium modular ice making, refrigeration, and wine preservation experience. U-Line creates products focused on functionality, style, and inspired innovations — paying close attention to even the smallest details. Applications include residential, outdoor, ADA height compliant, marine, and commercial.
QUICK START GUIDE u-line.com This Quick Start Guide covers the basics of installation and general use of your product.
QUICK START GUIDE u-line.com Safety and Warning ! DANGER NOTICE This unit contains R600a (Isobutane) which is a Please read all instructions before installing, flammable hydrocarbon. It is safe for regular operating, or servicing the appliance. use. Do not use sharp objects to expedite defrosting.
QUICK START GUIDE 16-1/2" 90° Door Swing Environmental Requirements 16-1/2" 90° Door Swing u-line.com NOTICE Stainless Black and White Models Electrical installation mustModels observe all state and local codes. This unit requires connection to a This model is intended for indoor/interior applications only 2115WC Models grounded (three-prong), polarized receptacle and is not to be used in installations that are open/ Wall Wall electrician.
USER QUICKGUIDE START GUIDE u-line.com u-line.com Door Adjustments 6. Tighten top hinge screws and replace hinge cover. HINGE COVER REVERSING THE DOOR Hinge cover included with the literature bag is optional. Location of the unit may make it desirable to mount the door on the opposite side of the cabinet. To install hinge cover: The hinge hardware will be removed and reinstalled on the Press hinge cover squarely over hinge opposite side of the cabinet.
USER GUIDE QUICK START GUIDE u-line.com Install top hinge and door: 4. Remove door by tilting forward and lifting door off bottom hinge. Retain shoulder washers; they will be Top Hinge Right Side reused. 5. Remove three screws from hinge holes on the opposite side. Reinstall into holes where the hinge was removed. Take care not to scratch cabinet. Top Hinge Left Side Pivot Screw Remove bottom hinge: 1. Remove bottom hinge from cabinet using 1/4” socket. 1.
QUICK START GUIDE u-line.com General Installation The following components are shipped inside the unit: 1. Double Tower (faucets, handles, gaskets, & hardware) 2. Nitrogen regulator (hose and valve) 3. Infuser regulator (hoses & hardware) 4. Liquid jumper line (with in-line filter) and gas jumper line 5. 2.5-gallon ball tap keg (you may use 3-gallon or 5-gallon keg) 6. Drip tray 7. Cleaning solution (2-ounce packet) (Additional cleaner, ULACOFFEECLEAN, is available at u-line.
QUICK START GUIDE u-line.com Install Tower on Free-Standing Refrigerator If your refrigerator is new out of the box, do not remove all the protective film on the stainless exterior until the tower is installed. 1. Remove four Phillips screws (secured with nuts on the inside of the refrigerator) and lift off cap to reveal tower mounting hole. Peel back enough film for tower to clear. 2. Position gasket over mounting hole and install tower using four Phillips screws and nuts. 3.
QUICK START GUIDE u-line.com Install Tower on Countertop (See template on next page) Note: These instructions are designed for a standard 36" countertop application. Note: For a customized fit, it may be necessary to acquire screws that are sized to the thickness of your countertop. 1. Position keg refrigerator under countertop to determine the desired depth. 2. Use the dimensions from Diagram A to determine the center point of the tower mounting hole. 3.
QUICK START GUIDE u-line.com Template for Countertop Installation Note: Verify template has printed true to scale - double check hole dimensions and placement.
QUICK START GUIDE u-line.com Assemble and Connect Regulator to Nitrogen Tank 1. Connect Keg to Dispenser Tower 1. Attach ball valve to tank regulator. Tighten with an adjustable wrench. Make sure valve is in the off position - turned clockwise as far as it can go. Attach black nitrogen coupler of the liquid jumper line to keg. With your thumb on top of the coupler, pull up on collar and press coupler down firmly onto out valve. Release collar - listen for a click.
QUICK START GUIDE 4. u-line.com Attach other end of hose to the single connection within the beverage tower. 3. Attach gray coupler of the gas jumper line to keg. With your thumb on top of the coupler, pull up on collar and press coupler down firmly onto in valve. Release collar - listen for a click. Pull up on the coupler to ensure it is locked down. In Valve Other end is connected to Infuser Regulator Connect Nitrogen Tank to Keg 1. Attach nitrogen line to ball valve on tank regulator.
QUICK START GUIDE u-line.com Connections When complete, the connections should look like this: Infuser Regulator Tank Regulator Nitrogen Tank Keg Filter Assembly LEVELING INFORMATION 1. 2. Use a level to confirm the unit is level. Level should be placed along top edge and side edge as shown. 3. Confirm the unit is level after each adjustment and repeat the previous steps until the unit is level. When ready to use, see FIRST USE section in this manual.
QUICK START GUIDE u-line.com Control Operation CONTROL FUNCTION GUIDE FUNCTION COMMAND NOTES ON/OFF Press Unit will turn On or OFF Adjust Temperature Press and hold for 5 seconds When the display is flashing, press or and release or to adjust the set point temperature. Note: temperature displayed is the actual temperature inside unit Toggle between ºF / ºC Hold and for 5 seconds The display will change units First Use Fill the Keg Initial startup requires no adjustments.
QUICK START GUIDE 4. Remove keg from refrigerator. 5. Lift handle and remove lid. u-line.com TO ADJUST PRESSURE 1. Loosen locking nut, turn adjusting screw until desired pressure is reached, and retighten locking nut. Regulated Gauge Tank Pressure Gauge 6. Fill keg with cold brew. 7. Replace and lock down lid. 8. Reattach hoses. Locking Nut Adjusting Screw Set Nitrogen Pressure 2. The pressure should be set around 20 - 30 PSI. Start at 25 PSI on regulated gauge; 7 PSI at infuser regulator.
QUICK START GUIDE u-line.com Dispensing Coffee The left tap delivers still cold brew which is refreshing and less acidic than hot coffee. The right tap delivers nitrogen-infused coffee which is the ultimate cold brew experience. Thousands of micro-nitrogen bubbles are infused as the coffee is dispensed. This creates a naturally slightly sweet taste and thicker and smoother texture. Troubleshooting ISSUE No/reduced liquid flow through faucet(s).
QUICK START GUIDE u-line.com Airflow and Product Loading If any surface discoloring or rusting appears, clean it quickly with Bon-Ami® or Barkeepers Friend Cleanser® and a nonabrasive cloth. Always clean with the grain. Always AIRFLOW finish with Claire® Stainless Steel Polish and Cleaner or External • comparable product to prevent further problems.
QUICK START GUIDE u-line.com NOTICE Cleaning Solution Preparation The drain pan was not designed to capture the Follow safety instructions on packet. Mix ULACOFFEECLEAN with water created when manually defrosting. To 2 gallons of warm (100°F/38°C) prevent water from overflowing the drain pan potable water. and possibly damaging water sensitive flooring, the unit must be removed from cabinetry. Tap Heads To defrost: 1. Disconnect power to the unit. 2. Remove all products from the interior 3.
U-Line Corporation (U-Line) Limited Warranty One Year Limited Warranty For one year from the date of original purchase, this warranty covers all parts and labor to repair or replace any part of the product that proves to be defective in materials or workmanship. For products installed and used for normal residential use, material cosmetic defects are included in this warranty, with coverage limited to 60 days from the date of original purchase.