0. Exit
1. Thermistor1temperaturenotincludingosets.
2. Thermistor2temperaturenotincludingosets.
3. Thermistor3temperaturenotincludingosets.
4. Thermistor4temperaturenotincludingosets.
5. Thermistor1oset.(+/-10)
6. Thermistor2oset.(+/-10)
7. Thermistor3oset.(+/-10)
8. Thermistor4oset.(+/-10)
9. Thermistor 2 set point
10. Thermistor 3 set point.
11. Thermistor 4 set point.
12. DefrostInterval(0to99hr)
13. Defrostduration(0to99min)
14. ErrorLog(SeeAppxD)
15. Clearerrorlog(holdlightkeyuntilcleared)
16. Thermistor1dierential(+5)
17. Thermistor3dierential(+5)
18. Evaporatorfanondelay(0to99sec)
19. Evaporatorfanodelay(0to99sec)
20. Individual component toggle
- Option#0–Exit
- Option#1–Relay1
- Option#2–Relay2
- Option#3–Relay3
- Option#4–Relay4
- Option#5–Relay5
- Option#6–Relay6
- Option#7–DCOutput1
- Option#8–DCOutput2
- Option#9–DCOutput3
- Option#10–DCOutput4
- Option#11–DCOutput5
- Option#12–Serialoutput(Compressor)
21. Model number
22. LightAllSegments
23. ActivateDefrost/Harvest-pressandholdfor3
secondstoactivatedefrost/harvest
24. Defaults-pressandholdfor3secondsto
restoreallvaluestofactorydefaults.
25. MainSoftware(Displayonly)
26. LiveLogPeriod(frequencythatdataisoutput
todiagnosticsport)
27. Factorytestmode(0=O,1=On)
28. CompressorRPM
29. Freezetimeadjust(Model54only)
30. Harvesttimeadjust(Model54only)
31. Lowtempalarmlimit(Model55only)
32. Hightempalarmlimit(Model55only)
ERRORS
*Allerrorsareloggedinmemory.
*Onlydoorerrorisdisplayedonthedisplayandhasan
audible signal.
*For68118models,pumperrorisdisplayedviaalert
lightwithnoaudiblealert.
E1: Thermistor 1 open.
E2: Thermistor 2 open.
E3: Thermistor 3 open.
E4: Thermistor 4 open.
E5: Thermistor 1 shorted.
E6: Thermistor 2 shorted.
E7: Thermistor 3 shorted.
E8: Thermistor 4 shorted.
E9: Door 1 open error.
E10:(displayedas10):Door2open
E11:(displayedas11):Waterlevel(trayorreservoir)
high.
E12:(displayedas12):Waterlevellow.
E13:Augererror
P1: Pump circuit open
SERVICE MENU