USER GUIDE & SERVICE MANUAL Outdoor Collection ● UOCL115 / UOCP115 ● 15” Clear Ice Maker
USER GUIDE & SERVICE MANUAL u-line.
USER GUIDE u-line.com WELCOME TO U-LINE Congratulations on your U-Line purchase. Your product comes from a company with over five decades of premium modular ice making, refrigeration, and wine preservation experience. U-Line creates products focused on functionality, style, and inspired innovations — paying close attention to even the smallest details. Applications include residential, outdoor, ADA height compliant, marine, and commercial.
USER GUIDE u-line.com Safety and Warning NOTICE Please read all instructions before installing, operating, or servicing the appliance. Use this appliance for its intended purpose only and follow these general precautions with those listed throughout this guide: ! WARNING CALIFORNIA PROPOSITION 65 This product contains chemicals known to the state of California to cause cancer and birth defects or other reproductive harm. www.P65warnings.CA.
USER GUIDE u-line.com Disposal and Recycling ! DANGER RISK OF CHILD ENTRAPMENT. Before you throw away your old refrigerator or freezer, take off the doors and leave shelves in place so children may not easily climb inside. If the unit is being removed from service for disposal, check and obey all federal, state, and local regulations regarding the disposal and recycling of refrigeration appliances, and follow these steps completely: 1. Remove all consumable contents from the unit. 2.
USER GUIDE u-line.com Environmental Requirements This unit is designed to operate between 50°F (10°C) and 100°F (38°C). Higher ambient temperatures may reduce the unit’s ability to reach low temperatures and/or reduce ice production on applicable models. For best performance, keep the unit out of direct sunlight and away from heat generating equipment. In climates where high humidity and dew points are present, condensation may appear on outside surfaces. This is considered normal.
USER GUIDE u-line.com Electrical ! WARNING SHOCK HAZARD — Electrical Grounding Required. Never attempt to repair or perform maintenance on the unit until the electricity has been disconnected. Never remove the round grounding prong from the plug and never use a two-prong grounding adapter. Altering, cutting or removing power cord, removing power plug, or direct wiring can cause serious injury, fire, loss of property and/or life, and will void the warranty.
USER GUIDE u-line.com Cutout & Product Dimensions 14 15⁄16” (379 mm) PREPARE SITE Your U-Line product has been designed for either freestanding or built-in installation. When built-in, your unit does not require additional air space for top, sides, or rear. However, the front grille must NOT be obstructed, FRONT and clearance is required for an electrical connection in 28” (711 mm) the rear.
USER GUIDE Side-by-Side Installation u-line.com 3. Place bracket over holes and attach to unit with two screws removed in step 2 using a T-25 Torx driver. Two units may be installed side-by-side. Cutout width for a side-by-side installation is the cutout Tighten screws fully. 4. Gently push units into position. Be careful not to dimension of a single unit times two. No trim kit is required. However, 1/4" (6 mm) of space entangle the electrical cord or water line, if applicable. 5.
USER GUIDE u-line.com Water Hookup ! CAUTION PREPARE PLUMBING The water valve uses a standard 1/4” (6.35 mm) compression fitting. U-Line recommends using accessory water hookup kit Part # 80-54674-00. The kit includes a 10’ (3 m) braided Do not use any plastic water supply line. The line is under pressure at all times. Plastic may crack or rupture with age and cause damage to your home. flexible water supply line and a brass hose fitting.
USER GUIDE u-line.com 3. Locate water 8. Install retaining clip. valve in the front of the unit and thread water supply line through. NOTICE Route the water supply line through the unit so it does not come into contact with any internal components other than the solenoid valve. Normal operation creates some vibration. A water supply line contacting an internal component or cabinet wall can cause excessive noise during operation or damage to the line. 4.
USER GUIDE Drain u-line.com GRAVITY DRAIN Model numbers including “CL” or “NB” do not include a factory installed drain pump. Normal Proper Drain Model numbers including “CP” or “NP” include a factory installed drain pump. With Trap Poor Drainage, Water Will Back Up DRAIN CONNECTION ! CAUTION With Trap and Vent Proper Drain If your U-Line unit did not come with a factory installed drain pump you must use a gravity style drain connection.
USER GUIDE u-line.com FACTORY INSTALLED DRAIN PUMP If your drain line will run up to a stand pipe, disposal Y-Branch Tailpiece P60 Pump Required or spigot assembly, or does not otherwise meet the Air Gap (Optional Hook-Up) requirements for a gravity drain, you may have ordered a pre-installed U-Line P60 drain pump. Waste If you need to install a P60 drain pump into your unit, see Shut-Off Valve DRAIN PUMP section in the User Manual.
USER GUIDE u-line.com Anti-Tip Bracket 1. Slide unit out so screws on top of unit are easily accessible. 2. Remove the two screws from the opposite side of the hinge assembly using a T-25 Torx driver (see below). 3. Place bracket over holes and attach to unit with two screws removed in step 2 using a T-25 Torx driver. Tighten screws fully. 4. Gently push unit into position. Be careful not to entangle the electrical cord or water line, if applicable. 5.
USER GUIDE u-line.com General Installation INSTALLATION LEVELING INFORMATION 1. Use a level to 1. Plug in the power/electrical cord. 2. Gently push the unit into position. Be careful not to entangle the cord or water and drain lines, if confirm the unit is applicable. level. Level should 3. be placed along top Re-check the leveling, from front to back and side to edge and side edge side. Make any necessary adjustments. The unit’s top as shown.
USER GUIDE u-line.com Grille Installation REMOVING AND INSTALLING GRILLE ! WARNING Disconnect electric power to the unit before removing the grille. When using the unit, the grille must be installed. Removing the grille 1. Disconnect power to the unit. 2. Remove three screws (1). 3. Slide grille (2) away from bottom hinge and remove grille from unit. Installing the grille 1. Align notch (3) in grille with center screw on bottom hinge and slide grille behind hinge. 2.
USER GUIDE u-line.com Door Swing Wall 2-1/8" Min. (54 mm) 90° Door Swing Units have a zero clearance for the door to open 90°, when installed adjacent to cabinets. Stainless Steel models require 2-1/8" (54 mm) door clearance to accommodate the handle if installed next to a wall.
USER GUIDE u-line.com Door Adjustments TO REVERSE THE DOOR HINGE COVER Hinge cover included with the literature bag is optional. To install hinge cover: 1. Press hinge cover squarely over hinge. Hinge Cover Remove grille: Remove the grille (see GRILLE INSTALLATION section of this guide). DOOR ALIGNMENT AND ADJUSTMENT Align and adjust the door if it is not level or is not sealing properly. If the door is not sealed, the unit may not cool properly, or excessive frost may form in the interior.
USER GUIDE 2. cabinet. On some models there may be a nut behind Remove door by tilting forward and lifting door off one or both screws on either side. bottom hinge. Retain shoulder washers; they will be 3. u-line.com u-line.com Remove corresponding screws on opposite side of reused. Install bottom hinge: 4. Insert arrow clips into holes. 5. Remove door by tilting forward and lifting door off Install two or three screws, depending on model. Replace bottom hinge.
marks on door and firmly press gasket into place. (If the original adhesive no longer holds the gasket USER GUIDE in place, it may be necessary to apply a strip of u-line.com two-sided tape.) Install top hinge and door: Top Hinge Right Side Top Hinge Left Side Pivot Screw 1. Remove pivot screw from hinge, flip hinge over, and install the pivot screw in the same hole from the opposite surface. 2. Lift the door onto the bottom hinge. 3. Align edge of the hinge with the outer edge of the unit. 4.
USER GUIDE u-line.com Control Operation CONTROL FUNCTION GUIDE FUNCTION COMMAND NOTES ON/OFF Press Unit will immediately turn On or OFF Adjust ice thickness See “Ice” section Enable Sabbath Mode Disable Sabbath Mode Press and release The oF / oC symbol will flash briefly after 5 seconds.
USER GUIDE u-line.com Ice Your clear ice machine is pre-set to produce ice between the optimal dimensions illustrated below: ICE CUBE THICKNESS ADJUSTMENT Cube Details NOTICE 1/4" TO 1/2" (6.4 mm to 12.7 mm) DIMPLE Ice thickness adjustment should only be made one increment at a time. Allow ice maker 1/16" TO 1/8" (1.6 mm to 3.2 mm) ICE BRIDGE production to stabilize for 24 hours before rechecking ice thickness. Ice is produced in layers resulting in a clear cube.
USER GUIDE u-line.com Airflow and Product Loading NOTICE The unit requires proper airflow to perform at its highest efficiency. Do not block the front grille at any time, or the unit will not perform as expected. Do not install the unit behind a door.
USER GUIDE u-line.com Cleaning Using abrasive pads such as ScotchBrite™ will EXTERIOR CLEANING become blurred. cause the graining in the stainless steel to Vinyl Clad (Black or White) Models Clean surfaces with a mild detergent and warm water Rust not cleaned up promptly can penetrate the solution. Do not use solvent-based or abrasive cleaners. surface of the stainless steel and complete Use a soft sponge and rinse with clean water. Wipe with a removal of the rust may not be possible.
USER GUIDE u-line.com 5. Re-install the standpipe into the water trough. NOTICE Use only U-Line Ice Machine Cleaner (Part No. 80-54081-00), available from your dealer or direct from your local parts distributor. To locate a parts distributor near you, visit u-line.com. It is a violation of federal law to use this solution in Evaporator a manner inconsistent with its labeling. Use of any other cleaner can ruin the finish of the evaporator and will void the warranty.
USER GUIDE u-line.com 9. When water begins flowing over the evaporator (approximately 3 minutes), pour 1 packet of CLR cleaner into the water trough. The cleaning process will last approximately 45 minutes. 10.Dilute 1 tablespoon bleach in 1 gallon of warm water. Apply this solution to the entire inside of the storage area. Then rinse thoroughly with water. The unit will resume operation approximately 15 minutes after the automated cleaning process is completed.
USER GUIDE USER GUIDE u-line.com u-line.com SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE Cleaning Condenser INTERVAL - EVERY SIX MONTHS To maintain operational efficiency, keep the front grille free of dust and lint, and clean the condenser when necessary. Depending on environmental conditions, more or less frequent cleaning may be necessary. ! WARNING Disconnect electric power to the unit before cleaning the condenser. ! WARNING DO NOT touch the condenser fins.
USER GUIDE u-line.com Extended Non-Use VACATION/HOLIDAY, PROLONGED SHUTDOWN For questions regarding winterization, please call U-Line at 414.354.0300. The following steps are recommended for periods of extended non-use: 1. ! CAUTION Remove all consumable content from the unit. Damage caused by freezing temperatures is not 2. Disconnect the power cord from its outlet/socket and leave it disconnected until the unit is returned to service. 3. Turn off the water supply. 4.
USER GUIDE u-line.com SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE Troubleshooting • Evaporator: Refrigerant flowing through an evaporator may sound like boiling liquid. BEFORE CALLING FOR SERVICE If you think your U-Line product is malfunctioning, read • Condenser Fan: Air moving through a condenser may the CONTROL OPERATION section to clearly understand be heard. the function of the control.
Wire Diagram 30 11 22 12 Us e Open Yellow Orange Purple Black/Yellow Open Light Blue Black Open White Compressor Hot Gas Valve Water Valve Cond. Fan P P Waste Pump Circ. Pump (GROUND) GREEN W/YELLOW RELAY HOT NEUTRAL White Black 115 V EMBRACO COMPRESSOR OVERLOAD Wire Diagram Waste Pump Door switch Water shutoff Water dispenser Cond. temp Bin temp White light 1 fac e rI nt er 42375 _A USER GUIDE u-line.
USER GUIDE u-line.com Product Liability Field service technicians are authorized to make an initial assessment in the event of reported damages. If there are any questions about the process involved, the technician should call U-Line for further explanation. While inspecting for defects or installation issues, photos should be taken to document any damages or issues found.
USER GUIDE Warranty Claims The following information defines the parameters for filing a warranty claim: Units must be registered prior to warranty submittal. Customers may register at www.U-Line.com. A proof of purchase is required. We also accept the following information to update warranty: • Valid serial number needed • Valid model number needed • Claims must be submitted online at www.U-LineService.com • u-line.
USER GUIDE Parts 1 24 u-line.
USER GUIDE Parts 1 25 u-line.
USER GUIDE u-line.com Ordering Replacement Parts Parts may be ordered online at www.U-Line.com See our contact information below: www.U-LineService.com (with service login) Phone Number: +1.800.779.2547 NOTICE Use only genuine U-Line replacement parts. The use of non-U-Line parts can reduce speed of ice production, cause water to overflow from ice maker mold, damage the unit, and void the warranty. Warranty parts will be shipped at no charge after U-Line confirms warranty status.
USER GUIDE u-line.
USER GUIDE USER u-line.com u-line.com SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE Compressor Specifications ! DANGER OVERLOAD PROTECTOR Electrocution can cause death or serious injury. Burns from hot or cold surfaces can cause serious injury. Take precautions when servicing R S C this unit. STARTING RELAY Disconnect the power source. RELAY COVER ULIN_0576_AW Do not stand in standing water when working around electrical appliances.
USER GUIDE Troubleshooting - Extended u-line.com • Evaporator: Refrigerant flowing through an evaporator may sound like boiling liquid. SPECIFIC ERRORS AND ISSUES The advanced diagnostic capabilities of the electronic • be heard. controls utilized on the 1, 3, and 5 Class units allow for easy and thorough troubleshooting. • in the defrost cycle. the CONTROL OPERATION section of the manual, along a service mode menu and service menu selection explanations.
USER GUIDE u-line.com MAIN CONTROL Check Voltage At Wall Outlet The main control board is very robust and is rarely the cause of system issues. It is important to fully diagnose No Voltage Alert Customer Of Power Failure No Voltage Replace Power Cord No Continuity Replace Fuse Voltage the board for any suspected failures before attempting to remove the board for replacement or service.
USER GUIDE Relay & DC Outputs One of the primary functions of the main control is to operate the multiple relay and DC outputs during each cycle. Verify proper operation of these relays using the following procedure. 1. Enter “Relay Toggle” through the service menu. u-line.com PLUNGER SWITCH A plunger switch is used to monitor door state. When the door is closed it comes into contact with the plunger which closes a circuit which turns the light and display off.
USER GUIDE u-line.com b. APPENDIX any leakage addressed with a seal kit. (U-Line service part # 80-55371-13) E11: Sensor in base near fan detecting water This sensor is designed to detect water escaping the product due to any type of malfunction inside the machine.
USER GUIDE b. u-line.com If unit fills, the float switch is malfunctioning and d. needs to be replaced (part # 80-55538-00). 4. Check compressor operation. • If unit is 3 Class product, enter service mode and operating, diagnose and fix system problem. activate relays 1 and 4 to determine if unit fills with • water. a. • If there is power, check valve resistance to connections to auger. 3.
USER GUIDE u-line.com Control Operation-Service CONTROL FUNCTION GUIDE UI BUTTON LAYOUT 1 1. 2 3 4 5 6 Hidden Button -Access Service Menu -No LED directly above. All LEDs turn on with button 2.
USER GUIDE u-line.com SERVICE MODE GUIDE SERVICE MODE GUIDE 0. Exit 1. Thermistor 1 temperature not including offsets. 2. Thermistor 2 temperature not including offsets. 3. Thermistor 3 temperature not including offsets. 4. Thermistor 4 temperature not including offsets. 5. Thermistor 1 offset. (+/- 10) 6. Thermistor 2 offset. (+/- 10) 7. Thermistor 3 offset. (+/- 10) 8. Thermistor 4 offset. (+/- 10) 9. Thermistor 2 set point 10. Thermistor 3 set point. 11. Thermistor 4 set point. 12.
USER GUIDE u-line.com 15. CLEAR ERROR LOG To clear errors, press and hold (5 seconds) when CLR is flashing. 16. THERMISTOR - 1 DIFFERENTIAL This number should not be adjusted 17. Does not apply to this model 18. Does not apply to this model 19. Does not apply to this model 20.
USER GUIDE u-line.
Comp/Fan Compressor Compressor Clear Ice, 3 Class **BV315-***1A 01 Control Operation-Service 47 Compressor Compressor Compressor **WD524-***1A **RF124-***1A **RI124-***1A 46 48 52 50 Compressor Compressor **BD524-***1A **WD324-***1A 43 Compressor Compressor **WC336-***1A **BD324-***1A 40 Compressor **WC524-***1A 37 38 41 Compressor Compressor **WC324-***1A **WC515-***1A 35 Compressor Compressor **WC315-***1A **WC318-***1A 32 Compressor **KR524-***1A 27 29 33 Compresso
USER GUIDE Thermistor u-line.com Thermistor Resistance Data Thermistors are used for various temperature readings. Thermistors provide reliable temperature readings using a resistance which varies based on surrounding temperatures. If a faulty thermistor is suspected, it may be tested using an accurate ohmmeter. Thermistor connections must be kept clean.
U-Line Corporation (U-Line) Limited Warranty One Year Limited Warranty For one year from the date of original purchase, this warranty covers all parts and labor to repair or replace any part of the product that proves to be defective in materials or workmanship. For products installed and used for normal residential use, material cosmetic defects are included in this warranty, with coverage limited to 60 days from the date of original purchase.