Specifications

76
®
SPECIFICATIONS (continued)
Setting FO2:
• Automatically set for 'Air' upon activation
Remains set for Air unless an FO2 numerical value is set
Nitrox set points from 21 to 50 %
If set for 21%, remains set for 21% until changed
If set for >21%, reverts to 50% 10 minutes after the dive (however,
if the FO2 Default setting is OFF, the previous value set will be
retained)
ACCESSORIES
Optional items available from your Authorized Oceanic Dealer:
• Battery Kit - includes 1 battery, 1 o-ring, silicon grease
• Lens Protector - adheres to lens face, prevents scratches
• OceanLog™ for Data Plus 2 - PC Download Package
(hardware and software program)
OPERATIONAL PERFORMANCE (continued)
Altitude:
• Operational from sea level to 14,000 feet (4,267 meters) elevation
• Recalibration of depth readings from 'feet of sea water' to 'feet of fresh water'
when higher than 2,000 feet (610 meters) elevation
Power:
• Battery 1 - 3.6 volt, 1/2AA TADIRAN
®
model TL-2150, .95Ah,
1.0ma, Lithium (must be 3.6 v, .95Ah, 1.0ma rating)
• Shelf life Up to 5 years
• Replacement User replaceable (annual recommended)
• Life expectancy 350 dive hours (if 1 - 1 hour dive per dive day) to over
700 dive hours (if 2 or more 1 hour dives per dive day).
Yearly replacement is recommended.
Activation:
Manual (push button) - cannot be activated by water immersion
Cannot be activated deeper than 4 feet (1.5 m)
Cannot be activated at elevations higher than 14,000 feet (4,267 m)
Needed before first dive.
Automatically shuts off if no dive is made within 120 minutes after initial
activation. Reactivation required.
Cannot be shut off manually.