User's Manual

40
System Scan Modes
Free run 120 scans per sec typical
Timed interval 100, 50, 20, 10 scans per sec
Shaft encoder 10, 25, 50, 100, 250, 500, 1000 mm
Head Electronics Unit (Tx-Rx)
Dimensions 300 mm x 220 mm x 90 mm
Weight 2 kg
Total system dynamic range >130 dB
Receiver dynamic range >90 dB
Time range minimum 6.4 ns
Time range maximum 820 ns
Pulse repetition time 1 µs
Effective bandwidth (typical) 2 GHz
500 MHz Antenna (P – 0500)
Dimensions 400 mm x 400 mm x 250 mm
Weight 4.0 kg
Pulse duration (typical) 0.9 ns
Environmental & build specifications
Temperature +1° to +40ºC
Humidity 10% to 90% non condensing
Sealing IP55
EMC Directive 89/336/EEC
Low Voltage Directive 72/23/EEC
CE Marked according to 93/68/EEC