Technical data
PD_OpManPS-4_05_us.fm
ELAU AG PacDrive PS-4 / PD-8  page 33
5.7 Commissioning
Hard-copy for correction
Electrical
connections of
PS-4
 Make connections for X1 and X2 according to the wiring 
diagram. (Wiring examples: See also "Electrical connections" on 
page 53.)
 Connect the prefabricated cable (PS-4/PD-8) with X4.
Insert the prefabricated SERCOS cable into X8 and snap it on.
Fig. 5-2: Assignment for connections to PD-8
Electrical
connections of
PD-8
 Remove the blind plugs ("power in" and SECOS in) from the 
cable ducts on the PD-8.
Fig. 5-3: PD-8 cable ducts
 Insert the PS-4/PD-8 connection cables in the "power in" 
opening.
 Insert the SECOS cable in the opening "SERCOS in".
PD_Inb_PD-8_1_us.fh8
1
2
5 / 6
DC+
DC-
PE
24V
24V
0V
0V
all shields
7 / 8
PD-8
connecting cable PS-4/PD-8
PE
DC+
DC-
SCL 1 SCL 2 SCL 3 SCL 4 SCL 5 SCL 6 SCL 7 SCL 8
24V
0V
PE
DC+
DC-
24V
0V
SERCOS in SERCOS out
to next PD-8
Power in Power out
PD-8_Ansch.fh
8
SERCOS in SCL055 (1) SCL055 (3) SCL055 (5) SCL055 (7) SERCOS out
Power in SCL055 (2) SCL055 (4) SCL055 (6) SCL055 (8) Power out