5.8 Configuration /
Hard-copy for correction
NOTE
The two jumpers must be placed in "closed" position over the
SERCOS connector only at the connection of the last PacDrive
SCL-055, even if several PD-8s are used. This closes the SERCOS
ring.
The physical order of the SERCOS slaves is different from the
numbers on the PD-8 cable ducts.
Check safety functions such as the EMERGENCY OFF switch.
Continue
commissioning.
the plant according to the operating manual of the packaging
machine producer.
Information on the connection of the PacDrive SCL to the PacDrive
PD-8 is available in the "PacDrive SCL" operating manual. Further
information on the slaves in the SERCOS ring and system solutions
with air barriers can also be found in the "PacDrive SCL" operating
manual.
5.7.1 Slaves in the SERCOS ring
Removing a single PacDrive SCL from the SERCOS ring
For test purposes, single PacDrive SCLs can be removed from the
SERCOS ring during commissioning or when exchanging units.
Proceed as follows:
Remove the connector of the corresponding SCL.
Insert a SERCOS jumper (Art. no. 53150032) in the free place.
9 The SCL in the SERCOS ring has now been substituted.
Fig. 5-5: SERCOS jumper as SCL substitute
5.8 Configuration / Programming / Diagnosis
The PacDrive PS-4 is matched by ELAU. The customer needs not
match them.
Error diagnosis and monitoring of operating states are done in the
PacDrive
controllers. For information, consult the corresponding
manuals.
In addition, diagnosis is possible by means of the LEDs on the