Influence of the PS-4 signals on the SCL
There is no HardwareEnable input on the SCL. However, the input
HardwareEnable, the signal PowerSupplyEnable and error
messages of the PS-4 have to lead to reactions in the SCL.
Therefore the following signals are sent from the PacDrive PS-4 to
the MAx-4:
PS-4 is active
Class 1 error message from PS-4
Error message with error reaction A from PS-4.
The ramping-down of the motor (error reaction B) is initiated in the
SCL if the PS-4 is reported to be inactive or an error message with
error reaction B is reported from the PS-4.
In case of error messages with error reaction A from the PS-4, the
final stages of the corresponding SCL are switched off immediately.
The motor coasts to a stop. The SCL behaves like an MC-4 on
which CoastEnable is set and HardwareEnable is deactivated. No
error message is triggered.
NOTE
The function "InverterEnable" is not integrated in the PacDrive PS-4.
A safety connection has to be implemented by means of a RDY
contact.