Technical data
PD_OpManPS-4_07_us.fm
ELAU AG PacDrive PS-4 / PD-8  page 47
7.1 PacDrive PS-4
Hard-copy for correction
7 Technical Data
7.1  PacDrive PS-4
7.1.1  General
PacDrive PS-4/10/16/230
Table 7-1: Technical data PacDrive PS-4 /10/16/230
Parameter Value
Article name PS-4 / 10 / 16 / 230
Order number 13 13 02 58
Supply
- rated connected voltage
- mains frequency
- control voltage/current
rotary current
3 AC / 1 AC 220V (-10%) to 240V (+10%) 
48 .. 62 Hz
DC 24 V (-15%..+25%) / max 13 A
own consumption max. 1 A
DC-circuit
- DC-circuit voltage
- capacity
- U
Bleeder
 ON
- U
Bleeder
 OFF
- excess voltage
- bleeder resistance
- bleeder - permanent power
- bleeder - peak power
DC 270 V to 370 V
660 µF (SCL cap.)
DC 410 V
DC 400 V
DC 430 V
21.5 Ohm
100 W
7 kW
Motor connection
- DC-circuit voltage
- DC-circuit permanent current
- DC-circuit peak current (1s)
- control voltage
- permanent current
- peak current (1s)
DC 270 V to 370 V
16 A (for supply with 3 AC...)
10 A (for supply with 1 AC...)
32 A
DC 24V (like input voltage)
13 A
25 A
Stray power
- electronic supply
- bleeder (internal)
- power part
approx. 12 W
0 ... 100 W (depending on the application)
approx. 4 W / A
Inputs
- input voltage/current
- input filter:
DC 20..30V / 5 mA
5 ms
Outputs
- relay outputs DC 20..30 V / 2 A
Weight 3.5 kg
Ventilation internal fan
Ambient conditions
- protection means
- ambient temperature during 
operation
- for storage and transport
- insulation
- excess voltage category
- excess voltage resistance
- degree of radio interference
IP20
+5 .. +45 °C (+55 °C with reduced power -
2% per K at I
NC
 and I
SC
)
-25 .. +70 °C
degree of pollution 2 ..., no dewing allowed
K III, T2 (DIN VDE 0110)
class 1 (DIN VDE 0160)
class A EN 55011 / EN 61800 - 3
Approvals in preparation