Technical data

PD_OpManPS-4_07_us.fm
ELAU AG PacDrive PS-4 / PD-8 page 49
7.1 PacDrive PS-4
Hard-copy for correction
X1 - Control signals
Table 7-2: Connection X1 - control signals
X2 - Control Voltage and Mains Connection
Table 7-3: Connection X2 - control voltage and mains connection
15
48
Pin Designation Meaning Range
max. cross
section
1 HW enable Hardware enable DC24V (pursuant to
IEC61131-2 type I)
1.5 mm
2
2 0 V 1.5 mm
2
3 DC dis DC-circuit discharge DC24V (pursuant to
IEC61131-2 type I)
1.5 mm
2
4 0 V 1.5 mm
2
5
*)
RDY + Ready contact (opens
in case of an error)
DC 20...30 V / 2 A 1.5 mm
2
6
*)
RDY - Ready contact DC 20...30 V / 2 A 1.5 mm
2
7 NC not connected 1.5 mm
2
8 NC not connected 1.5 mm
2
*) The Ready contact indicates that the PS-4 and the connected components are
ready for operation. If the Ready contact is closed, the system is ready for
mains connection. In case of an error, the Ready contact opens.
The ready contact has to be included in the mains contactor control, so that the
mains is switched off in case of an error.
PE
L1
L2
L3
+24V
0V
Pin Designation Meaning Range
max.
cross
section
1 24 V 24 V control voltage -15%..+25% 4 mm
2
2 0 V 0 V control voltage 4 mm
2
3PE
Protective conductor
connection
4 mm
2
4 L1 Phase L1
3AC/1AC 220..240 V
4 mm
2
5 L2 Phase L2
3AC/1AC 220..240 V
4 mm
2
6 L3 Phase L3
3AC/1AC 220..240 V
4 mm
2