0G 16-Port Managed Aggregation Switch Model: ES-16-XG
Introduction Thank you for purchasing the Ubiquiti Networks® EdgeSwitch™ XG. This Quick Start Guide is designed to guide you through installation and also includes warranty terms. Package Contents EdgeSwitch XG Power Cord Rack-Mount Brackets (Qty. 2) Bracket Screws (M4, Qty. 8) 10G 16-Port Managed Aggregation Switch Model: ES-16-XG Mounting Screws (#10-32 x 5/8", Qty. 4) Cage Nuts (#10-32 x 5/8", Qty. 4) Quick Start Guide TERMS OF USE: All Ethernet cabling runs must use CAT6A (or above).
Installation Requirements • Phillips screwdriver (for rack- or wall-mounting) • Standard-sized, 19" wide rack with a minimum of 1U height available (for rack-mounting) • Use compatible fiber SFP+ modules with the appropriate fiber optic cabling. For information about compatible fiber SFP+ modules, visit: community.ubnt.com/edgemax • For indoor applications, use Category 6A (or above) UTP cabling approved for indoor use.
Front Panel LEDs System SFP+: Speed/Link/Act RJ45 13-16 SFP+ 1-12 System LED RJ45: Speed/Link/Act State Status White Ready for Use Blue Bootup in Progress Flashing Indicates Reset to Factory Defaults Off No Link Speed/ Green Link/ Act Link Established at 1 Gbps Flashing Indicates Activity White Link Established at 10 Gbps Flashing Indicates Activity Off No Link Speed/ Green Link/ Act White Link Established at 1 Gbps Flashing Indicates Activity Link Established at 10 Gbps Flashing Indi
Front Panel Button Reset Button Description There are two methods to reset the EdgeSwitch XG to factory defaults: Runtime Reset (Recommended) Reset The EdgeSwitch XG should be running after bootup is complete, and the System LED is white. Press and hold the Reset button. The EdgeSwitch XG will reboot, and the System LED becomes blue after three seconds. Continue to hold the Reset button for about 15 seconds until the System LED flashes blue for two seconds.
Back Panel Console Port Console Port Console Description RJ45 serial console port for Command Line Interface (CLI) management. Use an RJ45‑to-DB9, serial console cable, also known as a rollover cable, to connect the Console port to your computer.
Back Panel Power DC Input Power DC Input The 25VDC input can connect a redundant or stand‑alone DC power source (not included) with minimum power: 56W, 25 to 16V, and 2.5 mm DC power inline connector. Note: You can use the redundant DC power source as a hot spare; if the internal AC/DC power supply no longer provides power, then the EdgeSwitch XG will switch to the DC power source without interrupting its operation. Power Connect the included Power Cord to the Power port.
Hardware Installation The EdgeSwitch XG can be placed on a horizontal surface, mounted on a wall, or mounted in a rack. WARNING: FAILURE TO PROVIDE PROPER VENTILATION MAY CAUSE FIRE HAZARD. KEEP AT LEAST 20 MM OF CLEARANCE NEXT TO THE VENTILATION HOLES FOR ADEQUATE AIRFLOW. Mounting in a Rack (Optional) 1. Attach the Rack-Mount Brackets to the EdgeSwitch XG using the eight Bracket Screws. 2. Attach the EdgeSwitch XG to the rack or wall using the four Mounting Screws.
Connecting Power 1. Connect the Power Cord to the Power port of the EdgeSwitch XG. 2. Connect the other end of the Power Cord to a power outlet.
Connecting SFP+ 1. Remove the protective plug covering the SFP+ port. 2. Plug a compatible fiber module into the SFP+ port. D D M M K 0 m 2 n CS 0 1 /M 3 1 S xR s /m pb n M 0 0 5 0 5 0 1 1 xT 3. Connect the fiber optic cable to the fiber module. Then connect the other end of the cable to another fiber device. 4. Repeat steps 1-3 to connect additional SFP+ ports.
Connecting RJ45 1. Connect an Ethernet cable from your computer or host system to any RJ45 port of the EdgeSwitch XG. 2. Connect Ethernet cables from the RJ45 ports of your devices to the other RJ45 ports of the EdgeSwitch XG.
Accessing the Configuration Interface The EdgeSwitch XG is set to DHCP by default, so it will try to automatically obtain an IP address. If that fails, then it will use the default fallback IP address, 192.168.1.2. Proceed to the appropriate section, DHCP or Fallback IP Address: DHCP Use one of the following methods: • Set up the DHCP server to provide a specific IP address to the EdgeSwitch XG based on its MAC address (on the label).
Fallback IP Address 1. Ensure that your computer (or other host system) is connected to the EdgeSwitch XG. 2. Configure the Ethernet adapter on your host system with a static IP address on the 192.168.1.x subnet. 3. Launch your web browser. Type the appropriate IP address in the address field (192.168.1.2 is the default fallback IP address). Press enter (PC) or return (Mac). 4. The login screen will appear. Enter ubnt in the Username and Password fields.
5. The EdgeSwitch Configuration Interface will appear. Go to System > Connectivity > IPv4. 6. Change the IP Address to a unique IP address or select DHCP on the IPv4 tab. Click Submit. Note: If you change the IP settings, then the session will be cut off, and you will need to reconnect to the EdgeSwitch XG using the new IP address. Customize additional settings as needed. For more information, refer to the EdgeSwitch documentation, which is available at documentation.ubnt.
Specifications ES-16-XG Dimensions Weight With Mount Brackets Total Non-Blocking Line Rate Max. DC Power Consumption Power Method AC DC Power Supply Supported Voltage Range Certifications Rack-Mount ESD/EMP Protection Operating Temperature 443 x 221 x 43 mm (17.44 x 8.70 x 1.69") 2.62 kg (5.78 lb) 2.71 kg (5.97 lb) 160 Gbps 36W (excludes SFP/SFP+ module) 100-240VAC/50-60 Hz, Universal Input DC 56W, 25 to 16V, with 2.
Safety Notices 1. Read, follow, and keep these instructions. 2. Heed all warnings. 3. Only use attachments/accessories specified by the manufacturer. WARNING: Failure to provide proper ventilation may cause fire hazard. Keep at least 20 mm of clearance next to the ventilation holes for adequate airflow. WARNING: To reduce the risk of fire or electric shock, do not expose this product to rain or moisture. WARNING: Do not use this product in location that can be submerged by water.
Limited Warranty UBIQUITI NETWORKS, Inc (“UBIQUITI NETWORKS”) warrants that the product(s) furnished hereunder (the “Product(s)”) shall be free from defects in material and workmanship for a period of one (1) year from the date of shipment by UBIQUITI NETWORKS under normal use and operation.
Disclaimer EXCEPT FOR ANY EXPRESS WARRANTIES PROVIDED HEREIN, UBIQUITI NETWORKS, ITS AFFILIATES, AND ITS AND THEIR THIRD PARTY DATA, SERVICE, SOFTWARE AND HARDWARE PROVIDERS HEREBY DISCLAIM AND MAKE NO OTHER REPRESENTATION OR WARRANTY OF ANY KIND, EXPRESS, IMPLIED OR STATUTORY, INCLUDING, BUT NOT LIMITED TO, REPRESENTATIONS, GUARANTEES, OR WARRANTIES OF MERCHANTABILITY, ACCURACY, QUALITY OF SERVICE OR RESULTS, AVAILABILITY, SATISFACTORY QUALITY, LACK OF VIRUSES, QUIET ENJOYMENT, FITNESS FOR A PARTICULAR PUR
Note Some countries, states and provinces do not allow exclusions of implied warranties or conditions, so the above exclusion may not apply to you. You may have other rights that vary from country to country, state to state, or province to province. Some countries, states and provinces do not allow the exclusion or limitation of liability for incidental or consequential damages, so the above limitation may not apply to you.
Australia and New Zealand Warning: This is a Class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures. CE Marking CE marking on this product represents the product is in compliance with all directives that are applicable to it.
Español La Directiva 2012/19/UE exige que los equipos que lleven este símbolo en el propio aparato y/o en su embalaje no deben eliminarse junto con otros residuos urbanos no seleccionados. El símbolo indica que el producto en cuestión debe separarse de los residuos domésticos convencionales con vistas a su eliminación.
Declaration of Conformity Česky [Czech] UBIQUITI NETWORKS tímto prohlašuje, že toto UBIQUITI NETWORKS zařízení, je ve shod se základními požadavky a dalšími příslušnými ustanoveními směrnic 2014/30/EU, 2014/35/EU. Dansk [Danish] Hermed, UBIQUITI NETWORKS, erklærer at denne UBIQUITI NETWORKS enhed, er i overensstemmelse med de væsentlige krav og øvrige relevante krav i direktiver 2014/30/EU, 2014/35/EU.
Malti [Maltese] Hawnhekk, UBIQUITI NETWORKS, tiddikjara li dan il-mezz UBIQUITI NETWORKS huwa konformi mar-rekwiżiti essenzjali u dispożizzjonijiet rilevanti oħrajn ta ‘Direttivi 2014/30/UE, 2014/35/UE. Herved UBIQUITI NETWORKS, erklærer at denne UBIQUITI NETWORKS Norsk [Norwegian] enheten, er i samsvar med de grunnleggende kravene og andre relevante bestemmelser i direktivene 2014/30/EU, 2014/35/EU.
www.ubnt.com ©2015-2016 Ubiquiti Networks, Inc. All rights reserved. Ubiquiti, Ubiquiti Networks, the Ubiquiti U logo, the Ubiquiti beam logo, EdgeMAX, EdgeOS, EdgeSwitch, and TOUGHCable are trademarks or registered trademarks of Ubiquiti Networks, Inc. in the United States and in other countries. All other trademarks are the property of their respective owners.