Specifications

Date:26-JULY-2020
Page: 25
16.8 Association Group Info (AGI)
Association
Group
Name
Node
Count
Function
1 Lifeline 5 - Device Reset Locally Notification
- Sensor Binary Report
- Indicator Report
- Sensor Multilevel Report Temperature Auto report based on Configuration Parameter 0x22 Setting.”
- Battery Report
- Heat Alarm Notification Report (0x04)
- 0x00 = State idle
- 0x02 = Overheat no location support -
- 0x06 = Underheat no location support
- Water Alarm Notification Report (0x05)
- 0x00 = State idle
- 0x02 = Water leak detected no location support
- Power Management Notification (0x08)
- 0x00 = State Idle
- 0x11 = Battery Fluid is low
2
Built-in Leak
Sensor Probe
5
- Basic Set
- 0x00 = IDEL / CANCEL (Based on Configuration Parameter 0x41 Setting)
- 0xFF = TRIGGERED (Based on Configuration Parameter 0x40 Setting)
3
Remote Water
Detection Probe
5
- Basic Set
- 0x00 = IDEL / CANCEL (Based on Configuration Parameter 0x43 Setting)
- 0xFF = TRIGGERED (Based on Configuration Parameter 0x42 Setting)
4 Overheat Alarm 5
- Basic Set
- 0x00 = IDEL / CANCEL (Based on Configuration Parameter 0x45 Setting)
- 0xFF = TRIGGERED (Based on Configuration Parameter 0x44 Setting)
5 Underheat Alarm
(Freeze)
5
- Basic Set
- 0x00 = IDEL / CANCEL (Based on Configuration Parameter 0x47 Setting)
- 0xFF = TRIGGERED (Based on Configuration Parameter 0x46 Setting)