User's Manual Part 1

CL1TC-4 400W DVB-H Transmitter Commissioning and Operation
Product Manual, Rev. 1 38
6. Turn on the UPS by pressing the power button on the UPS front panel.
7. Turn on the playout server by pressing the power button on the playout server front
panel.
8. Turn on the modulator AC power switch located on the modulator rear panel. All
three front panel LED’s will flash while the modulator goes through its boot-up
process.
9. Turn on the HPA circuit breaker located in cabinet breaker panel 2.
10. Turn on the HPA AC power switch located on the HPA rear panel. The front panel
LCD and rear panel PWR OK LED’s will turn on.
5.3.2 Configuring the Transmitter
The transmitter has been factory confi
gured with the customer specified television standard,
channel bandwidth and centre frequency.
The user will be required to:
Configure the modulator network parameters for remote network access.
Configure the modulator transport stream input parameters.
Configure the transmission (modulation) parameters and network mode (MFN or SFN)
5.3.2.1 Configuring the Network Parameters
The modula
tor must be configured correctly, before it can be placed on a network and
operated remotely through either of the rear panel Ethernet connectors.
To configure modulator for remote operation, the user must:
1. Connect a PC to either of the modulator rear panel Ethernet connectors.
2. Open a Web browser.
3. Enter the default IP address of the modulator in the Web browser address bar.
4. When the login page appears, enter “admin” in the password field. Note: The
username field must be left blank.
5. Once logged in, navigate to System Parameters -> Network Parameters and re-
configure the modulator’s network parameters as desired – see Figure 5-1
. Note:
The Management port refers to Ethernet connector A, while the Second Etherport
refers to Ethernet connector B.
6. Once the Network Parameters have been re-configured, navigate to System
Parameters -> System Reset and reset the modulator – see Figure 5-2
. Note: The
modulator must be reset for Network Parameter changes to take effect.
7. Once the modulator completes it reboot process, connect your network device to the
modulator’s rear panel Ethernet connector.