User's Manual Part 1

CL1TC-4 400W DVB-H Transmitter Commissioning and Operation
Product Manual, Rev. 1 40
5.3.2.2 Configuring the Input Parameters
The modula
tor must be configured correctly, before it can lock to the input transport
stream.
1. Navigate to Config -> Input to configure the DVB-ASI or GbE (IP) input settings –
see Figure 5-3
.
2. When a transport stream is connected to ASI input, Selected Input can be configured
for automatic selection, or the user can select the DVB-ASI input connector
manually. No other input parameters need to be configured.
3. When a GbE transport stream is connected to either of the Ethernet connectors, IP
Input Interface, Input Stream Dst IP and Input Stream Dst Port must be configured
correctly.
Figure 5-3 Input Configuration
5.3.2.3 Configuring the Modulation Parameters
1. N
avigate to Config -> Modulator Mode to ensure Normal operation is selected – see
Figure 5-4
. Normal mode must be selected for OFDM carrier generation.
2. Navigate to Config -> Transmission to configure the network mode (MFN or SFN)
and/or configure the DVB-H modulation parameters – see Figure 5-5
.