User's Manual

Innovator CU5-1800BTD/BRD ATSC Transmitter/ Initial On Site
Regenerative Translator Turn On Procedure
Instruction Manual, Rev. 0 19
Typical System Operating Parameters
Typical Operating Parameters for a CU3
Parameter Typical Reading
Forward Power 100%
Reflected Power <5%
Power Supply Voltage 24 Volts
Heatsink Temperature 20º to 30º F above ambient temperature
Pin Attenuator Voltage 1 Volt to 5 Volts
Typical Operating Parameters for a CU30
Parameter Typical Reading
Forward Power 100%
Reflected Power <5%
Power Supply Voltage 28 Volts
Heatsink Temperature 20º to 30º F above ambient temperature
Pin Attenuator Voltage 1 Volt to 5 Volts
Typical Operating Parameters for a CU50
Parameter Typical Reading
Forward Power 100%
Reflected Power <5%
Power Supply Voltage 30 Volts
Heatsink Temperature 20º to 30º F above ambient temperature
Pin Attenuator Voltage 1 Volt to 5 Volts
Typical Operating Parameters for a CU100/125
Parameter Typical Reading
Forward Power 100%
Reflected Power <5%
Power Supply Voltage 39 Volts
Heatsink Temperature 20º to 30º F above ambient temperature
Pin Attenuator Voltage 1 Volt to 5 Volts
Typical Operating Parameters for a CU50 used as a Driver
Parameter Typical Reading
Forward Power 20-70% (Depending on output power level of system)
Reflected Power <3%
Power Supply Voltage 30 Volts
Heatsink Temperature 20º to 30º F above ambient temperature
Pin Attenuator Voltage 1 Volt to 5 Volts
Typical Operating Parameters for the external Amplifier Tray(s)
in a CU250 or higher power System
Parameter Typical Reading
Forward Power 100%
Reflected Power <5%
Power Supply Voltage 30 Volts
Heatsink Temperature 20º to 30º F above ambient temperature