User's Manual

2
3
[Applicable only to models designed for sale in the European Union: TruePower
models designed for the EU include Power Factor Correction (PFC) circuitry in accord
with European standard regulation code EN61000-3-2. By altering the input current wave
shape, PFC improves the power factor of the power supply and results in increased energy
efficiency, reduced heat loss, prolonged life for power distribution and consumption
equipment, and improved output voltage stability.]
Installation:
Note (not applicable to models designed for the European Union): Check the red
power supply voltage switch setting before installation. It should be the same as your local
power voltage (115V for North America, Japan, etc. and 230V for Europe and many other
countries). Change the voltage setting if necessary. Failure to take this precaution could
result in damage to your equipment and could void your warranty.
1. Disconnect the power cord from your old power supply.
2. Follow your computer case manual and open the case.
3. Disconnect all the power Connectors from the motherboard and from the peripheral
devices such as case fans, hard drives, floppy drives, etc.
4. Remove the existing power supply from your computer case and replace it with
the Antec power supply.
5. Connect the Power Connectors to your motherboard and peripheral devices.
6. Connect the case fans to the dedicated fan connectors.
Note: Do not connect other devices except fans to these connectors. You may
connect case fans to the regular 4-pin Peripheral connectors if you choose not to
utilize TruePower Circuitry on your case fans.
7. Connect the 3-pin fan signal connector to one of the fan connectors on your
motherboard.
Note: You do not need to connect the 3-pin fan signal connector in order to make
the power supply work if you choose not to monitor the speed of the fan.
8. Close the computer case.
9. Connect the power cord to the Antec power supply
Specifications:
1.0 INPUT:
1.1. VOLTAGE
1.2 FREQUENCY
47Hz ~ 63Hz
1.3 CURRENT
1.4 INRUSH CURRENT
115V/50A(max.), 230V/80A(max.) at 25°C cold start
1.5 POWER EFFICIENCY
68% (min.) at full load, 115/230Vac 60Hz/50Hz
2.0 OUTPUT:
Note:
1) The continuous maximum total output power
RANGE MINIMUM NOMINAL MAXIMUM UNITS
1 90 115 135 VRMS
2 180 230 265 VRMS
115V 230V
TRUE330 7A 4A
TRUE380 8A 5A
TRUE430 9A 5A
TRUE480 12A 6A
TRUE550 12A 6A
VOLTAGE +5V +12V +3.3V -5V -12V +5VSB
MAX. LOAD
TRUE330 30A 17A 28A 0.5A 1.0A 2.0A
TRUE380 35A 18A 28A 0.5A 1.0A 2.0A
TRUE430 36A 20A 28A 0.5A 1.0A 2.0A
TRUE480 38A 22A 30A 1.5A 1.0A 2.0A
TRUE550 40A 24A 32A 0.5A 1.0A 2.0A
MIN. LOAD 0A 0.8A 0A 0A 0A 0A
REGULATION ±3% ±3% ±3% ±5% ±5% ±5%
RIPPLE & NOISE 50 120 50 50 120 50
(mV)
TOTAL MAX. +5V,+12V & +3.3V
OUTPUT MAX. OUTPUT
TRUE330 330W 310W
TRUE380 380W 360W
TRUE430 430W 410W
TRUE480 480W 460W
TRUE550 550W 530W
TRUE330
TRUE380
TRUE430
TRUE330
TRUE380
TRUE430
TRUE330
TRUE380
TRUE430