User's Manual

350-Watt Digital VHF LB Transmitter Chapter 3, Installation and Setup Procedure
DT325B, Rev. 0 3-8
3.4.1.1: Axciter Upconverter Sled
Module LEDs on Front Panel
Status Indicators:
PLL: This illuminates Green when the
phase lock loop circuit is closed, Red if
unlocked.
STATUS: This illuminates Green if no
faults present, Red when a fault has
occurred in the upconverter.
AGC: This illuminates Green when in
Auto, Amber when in Manual.
3.4.1.2: Controller Module LEDs on
Front Panel
Status Indicators:
OPERATE - This illuminates Green when
transmitter is in operate.
FAULT - This illuminates Red when a
fault has occurred in the transmitter.
DC OK - This illuminates Green when the
DC outputs that connect to the modules
in the transmitter are present.
3.4.2: Front Panel LCD Screen for the
Driver/Amplifier Chassis Assembly
A 4 x 20 display located on the front of
the Control & Monitoring/Power Supply
Module is used in the Driver/Amplifier
Chassis Assembly for control of the
operation and display of the operating
parameters of the transmitter. Below
are the display screens for the system.
The and characters are special
characters used to navigate up or down
through the menu screens. Display text
flashes on discrete fault conditions for all
screens that display a fault condition.
When the transmitter is in operate mode,
the STB menu appears. When the
transmitter is in standby mode, the OPR
menu appears.
NOTE: The following screens are typical
of an operating Exciter but may be
different from the screens in your
system.