Display flashes
You may be exceeding the 200psia and
550psia working ranges, or selected a
refrigerant unsuitable for the current pressure
reading.
Disconnect pressure connection to system,
press ZERO to recalibrate
LCD has dim
contrast
Press LCD to increase contrast
Replace batteries with a fresh set
Display visibly
cracked
Contact the manufacturer for service
Condensation
inside display
window
Allow unit to warm to ambient temperature.
Open battery compartment and allow unit to
dehumidify in a dry or air-conditioned
environment for 24 hours.
Keys do not
respond
MIN/MAX CLR does not give visual results
when pressed in modes other than HI and LO,
but the pressure memory is cleared.
Contact the manufacturer for service
Pressure port
loose against
case
Tighten the speed nut using a deep socket or
wrench. Do not use excessive force. Apply
thread lock if desired
Mode changes
randomly
without MODE
key press
When the temperature probe is installed, it
automatically enters t/sh/sc modes.
When the temperature probe is removed, it
automatically enters normal mode.
Check that the temperature probe is properly
installed, fully mated and locked on the plug.
Cannot access t,
SH or SC
modes
Check that the temperature probe is properly
installed, fully mated and locked on the plug.
If either temperature sensor is defective, their
will be no t/sh/sc/dt showing up on the
display.