Product Overview

WWW.UEITEST.COM
TACK Kits - Plumbing
A. Clamp Pipe Adapter Uses
For commercial application - Being able to tell the
temperature of water inside a pipe. Checking/verifying
the reading on a mechanical temperature gauge to see
if it’s accurate. Also checking temperatures in pipes in
general.
B. Combustible Leak Detector Uses
New install checking gas connections, repair work and
finding gas leaks
C. Manometer Uses
With gas Water Heaters. The first question asked when
calling service is what is static pressure (Pressure while
not running). Second is dynamic pressure (pressure
while operating). If static is to low, it’s a problem. If
difference between static and dynamic is to great of a
water column/water gauge pressure drop. That is also a
problem.
D. Clamp Meter Uses
Checking line voltage (garbage disposal, Tankless water
heater, dishwashers (Do I have 110 or 220V power)
Checking low voltage (gas valve, any type
milliampmicroamp application)
Checking continuity (A prover switch on a commercial
Water Heaters. High limit switch on a
Tankless water heater, fusible link on a Tankless water
heater, is a circuit open or closed)
E. Thermometer Uses
Water proof. When setting a mixing valve. You go to
the closest hot water outlet. Put the thermometer in
the water stream and set the mixing valve correctly.
Probably 120 degrees. Same thing when setting shower
valves. Water proof because you put in water stream.
Any general use where water temperature needs to be
measured.
A.
B. C.
D. E.