User Manual
33
1.2.2.2. Robot Installation
The robotic arm has five M5 bolts provided and can be mounted
through five ∅5.5 holes in the base of the robotic arm. It is
recommended to tighten these bolts with a torque of 20N·m.
Robot Base Mounting (unit: mm)
1.2.2.3. Robotic Arm is Connected to the Control Box
Plug the connector of the Robotic Arm Power Supply Cable and the
Robotic Arm Signal Cable into the interface of the Robotic Arm. The
connector is a foolproof design. Please do not unplug and plug it
violently;
Plug the Robotic Arm Power Supply Cable and the Robotic Arm Signal
Cable into the Control Box;
Plug the Control Box Power Cable into the AC (110V-240V) interface on
the Control Box and the other end into the socket (as shown in Figure