the I/O of the robotic arm. 
1.
Interfering signals above the level specified in the 
IEC standard will cause abnormal behaviour of the 
robotic arm. Extremely high signal levels or 
excessive exposure can cause permanent damage 
to the robotic arm. UFACTORY (Shenzhen) 
Technology Co., Ltd. is not responsible for any loss 
caused by EMC problems. 
2.
The length of the I/O cable that used to connect 
the Control Box with other mechanical and plant 
equipment must not exceed 30 meters unless it is 
feasible after the extension testing. 
1.
 When wiring the electrical interface of the Control   
Box, the Control Box must be powered off. 
2.3. End-Effector I/O 
At the tool side of the robotic arm, there is an avionic socket 12-pin 
female industrial connector. This connector provides power and control 
signals for the grippers and sensors used on a particular robotic arm 
tool. Please refer to the figure below: 