Terminal
Parameter
Min. Value
Typical Value
Max. Value
Unit
Analog Input under Voltage Mode
[AIx - AG]
Voltage
0
-
10
V
[AIx - AG]
Resistance
-
10k
-
Ω
[AIx - AG]
Resolution
-
12
12
bit
Analog Output under Voltage Mode
[AOx - AG]
Voltage
0
-
10
V
[AOx - AG]
Current
0
-
20
mA
[AOx - AG]
Resistance
-
100k
-
Ω
[AOx - AG]
Resolution
-
12
-
bit
2.4.4.1. Analog Output
The following example shows how to use the analog speed control
input to control the conveyor belt.(Connect to AO0 or AO1)
2.4.4.2. Analog Input
The following example shows how to connect an analog
sensor.(Connect to AI0 or AI1)