【Warning】 
● When the robotic arm issues a warning, the output is low. 
Otherwise, the output is high. 
【Collision】 
● When the robotic arm reports an error of collision, the output is low. 
Otherwise, the output is high. 
【On manual mode】 
● When the Manual Mode is turned on, the output is low. 
Otherwise, the output is high. 
【Offline task running】 
● When the robotic arm is running the offline projects, the output is low.  
Otherwise, the output is high. 
【Reduced Mode】 
● When the reduced mode is turned on, the output is low, otherwise the 
output is high. 
【Robot Enabled】 
● When the manipulator is enabled,the output is low, otherwise, the 
output is high. 
Note:CO0-CO7 has the same function as DO0-DO7. 