User Manual
135 
method to reset the IP. 
Reset IP 
Steps to reset IP: 
1. Press the emergency stop button and turn off the power of the 
control box. 
2. Connect RI0 to GND with a cable. 
3. Turn on the power of the control box. After hearing the sound of 
"beep", it means that the IP address of the control box has been reset 
successfully. The reset IP is 192.168.1.111. 
4. Please unplug the cable connecting RI0 and GND and wait for the 
control box to start up (60 seconds). 
5. Enter 192.168.1.111 in the xArm Studio search box, connect the 
robotic arm. 