User Manual
47 
The electrical specifications are as follows: 
Parameter 
Min. Value 
Typical Value 
Max. Value 
Unit 
Supply Voltage in 24V 
- 
24 
30 
V 
Supply Current * 
- 
- 
1800 
mA 
Note: * It is strongly recommended to use a protection diode for inductive loads. 
Make sure that the connecting tool and the gripper 
do not cause any danger when the power is cut, such 
as dropping of the work-piece from the tool. 
2.3.1.  Digital Output 
The digital output is implemented in the form of NPN with an open 
collector(OC). When the digital output is activated, the corresponding 
connector will be driven to GND. When the digital output is disabled, 
the corresponding connector will be open (open collector/open drain). 
The electrical specifications are as follows: 
Parameter 
Min 
Typical 
Max 
Unit 
Open-circuit Voltage 
-0.5 
- 
30 
V 
Voltage when sinking 50mA 
- 
0.05 
0.20 
V 
Sink Current 
0 
- 
100 
mA 
Current through GND 
0 
- 
100 
mA 
There is no current protection on the digital output 
of the tool, which can cause permanent damage if 
the specified value exceeded. 