User Manual

52
[COx]
Current*
0
-
100
mA
[COx]
Voltage Goes
Down
0
-
0.5
V
[COx]
Open Drain
Current
0
-
0.1
mA
[COx]
Function
-
NPNOC
-
Type
Digital Input
[EIx/SIx/CIx/RIx]
Voltage
0
-
30
V
[EIx/SIx/CIx/RIx]
OFF Area
15
-
30
V
[EIx/SIx/CIx/RIx]
ON Area
0
-
5
V
[EIx/SIx/CIx/RIx]
Current0-0.5
3
-
8
mA
[EIx/SIx/CIx/RIx]
Function
-
-
-
Type
Note: ** For resistive or inductive loads up to 1H.
2.4.2. Dedicated Safety I/O
This section describes the dedicated safety inputs and their
configurations of the safety I/O. Please follow the universal
specifications in Section 2.4.1.
Safety devices and equipment must be installed to comply with the
safety instructions and risk assessment (see Chapter 1).
All safety I/Os exist in pairs (redundancy) and must be kept in two
separate branches. A single I/O failure should not result in the loss of
There is no current protection on the digital output of
the Control Box. If the specified values exceeded,
permanent damage may result.