User's Manual

99
11. Remove the Pump Master wire from the terminal
labeled “P/MV” or “Pump Master” and butt connect
it to the GRAY wire labeled P/M (V), from the “Valve
Bundle”, and crimp it so it’s attached securely.
12. Identify the BROWN wire labeled P/M (C) from the
“Clock Bundle” and attach it to the terminal in the ir-
rigation clock labeled “P/MV” or “Pump Master” where
you removed the wire in step 11 above.
13. Identify the common wire(s) in the irrigation clock,
detach them from the terminal and butt connect them
to the WHITE wire labeled COM OUT (V), from the
“Power Bundle”, and crimp them so they are attached
securely.
Depending on the number of common wires
present a wire nut may need to be used to twist all the
wires together instead of a butt connector.
14. Identify the TAN wire labeled COM IN (C) from the
“Power Bundle” and attach it to the common terminal
on the irrigation clock where the wires were removed
in step 13 above. When properly installed the wiring
should look like the figure to the right.