User manual

Intellibox Basic
48
Use the “Read” sub-menu to read and display long addresses. The
read procedure is initiated by pressing the E key.
Take note that even during a read operation bit 5 of CV 29 is set to
1. From that moment on, it will no longer be possible to control the
locomotive with its CV 1 “short” address, unless you reset bit 5 of
CV 29 to zero.
Use the “Program” sub-menu for programming addresses greater
than 127. The programming operation is initiated by pressing the
E key.
The long addresses programming procedure changes the
decoder’s CV 17, 18 and 29. After programming a long address, the
“short” address in CV 1 and the consisting address in CV 19 are no
longer available. If you want to use these addresses again, you
must set bit 5 of CV 29 to zero.
After entering a long address bit 5 of CV29 back to zero if the
decoder is to use the short address in CV1 again.
8.4.7 DCC programming error messages
If the programming operation of a DCC decoder fails, the top line of
the display will show one of the following error messages:
Error The read or write operations of a register or a CV has
failed.
no loc No locomotive is present in the programming track, or
the locomotive has a defective electrical contact with the
programming track.
short Short-circuit in the programming track.
Danger Electrical contact between the programming track and
the main track.
no pag The decoder doesn’t accept paged programming.
8.5 Programming of Motorola Decoders
The programming of Motorola decoders is described in the manual
of the respective decoder and carried out from the control panel.
8.6 Programming of mfx-Decoders
You can find a guide for the programming of mfx decoders on our
InterNet site www.uhlenbrock.de under Service-FAQ-Märklin
System.
Caution
Importan
t